| Model Number |
4158060S |
| Medical Device Problem Code |
Leak/Splash (1354)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/19/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|
Event or Problem Description
|
|
As reported, the balloon of an 8x6 80cm powerflex extreme percutaneous transluminal angioplasty (pta) balloon catheter leaked contrast at the proximal side of the balloon when inflated at five atmospheres (atm) pressure.The device was removed from the patient intact (in one piece).Another same size cordis balloon was used and worked well.The case was completed.There is no reported patient injury.The product was stored per labeling.The user is trained in the device.The device was used for a fistulagram.The product was stored properly according to the instructions for use (ifu).There was no difficulty removing the device from the hoop, removing the protective balloon cover, stylet, or any of the sterile packaging components.There were no kinks or other damages noted prior to inserting the product into the patient.The device was prepped normally and was able to maintain negative pressure.A non-cordis inflation device was used to inflate the balloon.The device will not be returned for evaluation.
|
| |
|
Event or Problem Description
|
|
As reported, the balloon of an 8x6 80cm powerflex extreme percutaneous transluminal angioplasty (pta) balloon catheter leaked contrast at the proximal side of the balloon when inflated at five atmospheres (atm) pressure.The device was removed from the patient intact (in one piece).Another same size cordis balloon was used and worked well.The case was completed.There is no reported patient injury.The product was stored per labeling.The user is trained in the device.The device was used for a fistulagram.The product was stored properly according to the instructions for use (ifu).There was no difficulty removing the device from the hoop, removing the protective balloon cover, stylet, or any of the sterile packaging components.There were no kinks or other damages noted prior to inserting the product into the patient.The device was prepped normally and was able to maintain negative pressure.A non-cordis inflation device was used to inflate the balloon.The device will not be returned for evaluation.
|
| |
|
Additional Manufacturer Narrative
|
|
As reported, the balloon of an 8x6 80cm powerflex extreme percutaneous transluminal angioplasty (pta) balloon catheter leaked contrast at the proximal side of the balloon when inflated at five atmospheres (atm) pressure.The device was removed from the patient intact (in one piece).Another same size cordis balloon was used and worked well.The case was completed with no reported patient injury.The product was stored per labeling and the user is trained in the device.The device was used for a fistulagram.The product was stored properly according to the instructions for use (ifu).There was no difficulty removing the device from the hoop, removing the protective balloon cover, stylet, or any of the sterile packaging components.There were no kinks or other damages noted prior to inserting the product into the patient.The device was prepped normally and was able to maintain negative pressure.A non-cordis inflation device was used to inflate the balloon.The product was not returned for analysis.A product history record (phr) review of lot 82235501 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿balloon leakage - during positive pressure¿ could not be confirmed as the device was not returned for analysis.The exact cause could not be determined.Vessel characteristics, although unknown and procedural factors likely contributed to the reported event.However, with the limited amount of information available regarding lesion characteristics and without the return of the device for analysis it is difficult to draw a clinical conclusion between the device and the event reported.According to the safety information in the instructions for use ¿balloon pressure should not exceed the rated burst pressure.The rated burst pressure is based on the results of in-vitro testing.At least 99.9% of the balloons (with a 95% confidence), will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over pressurization.Use only the recommended balloon inflation medium.Never use air or any gaseous medium to inflate the balloon.Prior to angioplasty, the catheter should be examined to verify functionality and ensure that its size and shape are suitable for the specific procedure for which it is to be used.¿ neither the phr nor the information available suggests a design or manufacturing related cause for the reported event.Therefore, no corrective or preventive action will be taken at this time.
|
| |
|