• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: PRIDE MOBILITY PRODUCTS PRIDE MOBILITY PRODUCTS; SCOOTER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PRIDE MOBILITY PRODUCTS PRIDE MOBILITY PRODUCTS; SCOOTER Back to Search Results
Model Number SC710 VICTORY 10 4 WHEEL
Medical Device Problem Code Appropriate Device Problem Term/Code Not Available (3191)
Health Effect - Clinical Code Bruise/Contusion (1754)
Date of Event 10/26/2022
Type of Reportable Event Serious Injury
Event or Problem Description
Consumer alleges he was driving up a ramp to his utility bldg.When he was just inside the doorway the scooter allegedly shot forward, stood up and allegedly knocked him out of the door with the scooter allegedly landing on his chest.
 
Additional Manufacturer Narrative
The device has not yet been made available for evaluation.Should further information or the device become available, a follow-up report will then be issued.
 
Event or Problem Description
Consumer alleges he was driving up a ramp to his utility bldg.When he was just inside the doorway the scooter allegedly shot forward, stood up and allegedly knocked him out of the door with the scooter allegedly landing on his chest.
 
Additional Manufacturer Narrative
The alleged inadvertent movement could not be duplicated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRIDE MOBILITY PRODUCTS
Common Device Name
SCOOTER
Manufacturer (Section D)
PRIDE MOBILITY PRODUCTS
401 york ave
duryea PA 18642
Manufacturer (Section G)
N/A
n/a
n/a
n/a
Manufacturer Contact
kelly livingston
401 york ave
duryea, PA 18642
5706024056
MDR Report Key15805020
Report Number2530130-2022-00094
Device Sequence Number17524912
Product Code INI
UDI-Device Identifier00606509300346
UDI-Public00606509300346
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K071949
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 02/23/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Model NumberSC710 VICTORY 10 4 WHEEL
Device Catalogue NumberN/A
Device Lot NumberN/A
Was Device Available for Evaluation? Device Returned to Manufacturer
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/02/2022
Supplement Date Received by Manufacturer02/17/2023
Initial Report FDA Received Date11/16/2022
Supplement Report FDA Received Date02/23/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/25/2022
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization;
Patient SexMale
-
-