MAUDE Adverse Event Report: STRYKER GMBH BONE SCREW VARIAX2 T10, FULL THREAD, 3.5MM / L20MM; SCREW, FIXATION, BONE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER GMBH BONE SCREW VARIAX2 T10, FULL THREAD, 3.5MM / L20MM; SCREW, FIXATION, BONE Back to Search Results
Model Number 657420
Medical Device Problem Code Positioning Failure (1158)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/20/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The reported event regarding the locking feature could be not confirmed, since the returned bone screw is not designed to be locked into the plate.The device inspection revealed the following: there is no failure of a bone screw mentioned in the event description.However, the evaluation of the screw has shown that the device is extremely damaged.The last thread flank below the screw head is completely flattened.The screw head is very strong deformed, a piece of the head is even sheared off on one site.Due to this damage the lot number is not present anymore.The t10 recess is deformed in, caused by very high forces in clockwise direction.All these damages are an indication for an extremely heavy contact between the screw and the plate.Afterwards it cannot be defined why such tremendous forces where applied onto this bone screw, the most likely explanation could be that the user thought it was a locking screw and tried to lock it in the plate.The damage pattern of the bone screw corresponds to the damage pattern of the proximal hole of the plate.By the corresponding marks at the screw and the plate it can be simulated in which extreme angle the screw was inserted into the plate during implantation.A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.Based on investigation, the root cause was attributed to a user related issue.The failure was caused by an extreme insertion angle of the screws, this did lead to an undue contact between the screws and the plate.This contact caused in this case a strong deformation of the locking hole at the plate and the bone screw.No indications of material, manufacturing or design related problems were found during the investigation.If more information is provided, the case will be reassessed.
 
Event or Problem Description
It was reported that as the screw progressed, it would not engage the locking mechanism.It was further reported that it spun freely losing all compression on the bone.A surgical delay of 45-minutes was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BONE SCREW VARIAX2 T10, FULL THREAD, 3.5MM / L20MM
Common Device Name
SCREW, FIXATION, BONE
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ  2545
Manufacturer (Section G)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ   2545
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key15825065
Report Number0008031020-2022-00618
Device Sequence Number20389098
Product Code HWC
UDI-Device Identifier07613327073874
UDI-Public07613327073874
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K180500
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 11/18/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number657420
Device Catalogue Number657420
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/01/2022
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/25/2022
Initial Report FDA Received Date11/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexFemale
-
-