Model Number H7493941838300
Medical Device Problem Codes Difficult to Advance (2920); Device Dislodged or Dislocated (2923)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/24/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that stent dislodgement occurred.The target lesion was located in the non-tortuous and mildly calcified vessel.A 3.00 x 38mm synergy xd drug-eluting was advanced for treatment.However, the stent was unable to deploy due to calcium and when the device was tried to pull back, the stent came off from the balloon in left main artery.The stent balloon was reinflated to remove the dislodged stent.The procedure was completed with a different device.No patient complications were reported.
 
Event or Problem Description
It was reported that stent dislodgement occurred.The target lesion was located in the non-tortuous and mildly calcified vessel.A 3.00 x 38mm synergy xd drug-eluting was advanced for treatment.However, the stent was unable to deploy due to calcium and when the device was tried to pull back, the stent came off from the balloon in left main artery.The stent balloon was reinflated to remove the dislodged stent.The procedure was completed with a different device.No patient complications were reported.
 
Additional Manufacturer Narrative
Device evaluated by mfr.: a synergy xd mr us 3.00 x 38mm stent delivery system was returned for analysis.The device was returned without the stent attached.A review of the manufacturing stent profile data was performed and the stent outer diameter is within max crimped stent profile measurement.The balloon cones were reviewed, and there were no signs of positive pressure applied.Crimp markings were visible.A visual and microscopic examination of the bumper tip showed no signs of damage.A visual and tactile examination of the hypotube shaft found multiple kinks along several locations of the hypotube shaft.A visual and tactile examination of the outer and mid-shaft section found no issues along the shaft.No other issues noted with device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY XD
Common Device Name
CORONARY DRUG-ELUTING STENT
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
jeff wallner
4100 hamline ave n
arden hills, MN 55112
6515811560
MDR Report Key15825854
Report Number2124215-2022-47827
Device Sequence Number17669551
Product Code NIQ
UDI-Device Identifier08714729981015
UDI-Public08714729981015
Combination Product (Y/N)Y
Initial Reporter StateTX
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/11/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/14/2023
Device Model NumberH7493941838300
Device Lot Number0027548932
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 11/01/2022
Supplement Date Received by Manufacturer03/29/2023
Initial Report FDA Received Date11/18/2022
Supplement Report FDA Received Date04/11/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/14/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-