• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BELMONT MEDICAL TECHNOLOGIES THE BELMONT RAPID INFUSER, RI-2; PUMP, INFUSION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BELMONT MEDICAL TECHNOLOGIES THE BELMONT RAPID INFUSER, RI-2; PUMP, INFUSION Back to Search Results
Model Number 903-00018P
Medical Device Problem Codes Leak/Splash (1354); Material Separation (1562)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/24/2022
Type of Reportable Event Malfunction
Event or Problem Description
During a procedure with an acutely bleeding trauma patient, an accidental incident occurred with a 3l reservoir.Where the return hose is connected to the reservoir, the weld broke in the middle of the transfusion, and the blood started gushing out over the rapid infuser.This happened after the trauma staff had been working for about 45 minutes with the rapid infuser.The belmont's distributor confirmed on (b)(6) 2022, that there was no patient injury as a result of the reported incident.
 
Additional Manufacturer Narrative
The internal complaint file#: (b)(4) has been logged for this incident for traceability.The ri-2 and disposable involved in the incident has been obtained by the distributor but has not yet been returned/ received by belmont medical technologies for evaluation.The user reported that during a procedure with an acutely bleeding trauma patient, an accidental incident occurred with a 3l reservoir.Where the return hose is connected to the reservoir, the weld broke in the middle of the transfusion, and the blood started gushing out over the rapid infuser.This happened after the trauma staff had been working for about 45 minutes with the rapid infuser.The distributor confirmed on (b)(6) 2022, that there was no patient injury as a result of the reported incident.Belmont have followed up on october 26th, october 28th and november 9th to obtain additional information but have not yet received any further information on the incident.The operator's manual provides instructions on installing the disposable set and additional recommended operator actions.The step-by-step procedures in manual has warning on installing the disposable, "do not kink or twist the tubing" and "do not apply excessive pressure to the pressure transducer.The pressure transducer can be damaged with excessive force.Do not use the system if the pressure transducer is damaged".All disposable sets are 100% visually inspected and 100% leak tested prior to final packaging and release for shipment from belmont medical technologies.Review of complaints confirms that this is an isolated incident.Belmont is waiting to get the device back for investigation.Without results of the device investigation, no conclusions can be drawn.A follow-up report will be submitted once the investigation is complete and additional information becomes available.
 
Additional Manufacturer Narrative
The impacted sample has not been returned to belmont for inspection.A review of the pictures provided by the distributor indicate that a separation occurred where the hose is connected to the reservoir.It is not possible to determine if the root cause of the separation was a handling issue or a manufacturing issue from the pictures provided.A review of the manufacturing records and retain sample indicate no issues for this lot and no other similar complaints have been received for this lot.Belmont confirmed that there was no patient injury as a result of the reported incident.This is regarded as an isolated incident and belmont shall continue to monitor for any similar incidents.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THE BELMONT RAPID INFUSER, RI-2
Common Device Name
PUMP, INFUSION
Manufacturer (Section D)
BELMONT MEDICAL TECHNOLOGIES
780 boston road
billerica MA 01821
Manufacturer (Section G)
BELMONT MEDICAL TECHNOLOGIES
780 boston road
billerica MA 01821
Manufacturer Contact
urja jani
780 boston road
billerica, MA 01821
MDR Report Key15849476
Report Number1219702-2022-00042
Device Sequence Number12341709
Product Code LGZ
UDI-Device Identifier00896128002008
UDI-Public00896128002008
Combination Product (Y/N)N
Initial Reporter CountryDA
PMA/510(K) Number
K141654
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/10/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number903-00018P
Device Catalogue Number903-00018P
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/26/2022
Supplement Date Received by Manufacturer10/26/2022
Initial Report FDA Received Date11/22/2022
Supplement Report FDA Received Date03/10/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-