SYNTHES GMBH 5.0MM TI LOCKING HEAD SCREW SELF-TAPPING 80MM; APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT
|
Back to Search Results |
|
Catalog Number 413.380 |
Device Problem
Break (1069)
|
Patient Problem
Metal Related Pathology (4530)
|
Event Date 06/05/2022 |
Event Type
Injury
|
Event Description
|
Device report from switzerland reports an event as follows: it was reported that patient underwent revision surgery on (b)(6) 2022, to remove plates and screws.The devices were implanted nine months prior.The surgeon noticed a strong metallosis.This report is for a screw.This is report 2 of 4 for (b)(4).Additional impacted products are captured on related complaint (b)(4).
|
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.The investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.G1: postal code-2540.Part # 413.380, lot # l975205, manufacturing site: werk grenchen, release to warehouse date: 12 jul 2018.The product was returned to depuy synthes for evaluation.The depuy synthes team conducted a visual inspection of the returned device.Visual analysis of the returned sample revealed that lockscr ø5 self-tap l80 tan was observed broken at the shaft, near of the screw head.The broken fragment was received in the evidence provided.A dimensional inspection for the clockscr ø5 self-tap l80 tan was unable to be performed due to post manufacturing damage.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.The overall complaint was confirmed as the observed condition of the lockscr ø5 self-tap l80 tan would contribute to the complained device issue.There is no indication that a design or manufacturing issue has caused the complaint condition and hence the root cause cannot be determined.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Drawing/specifications reviewed: -the following source controlled drawings reflecting the current and manufactured revisions were reviewed: -verriegelungsschraube 5*xx ss hex locking screw 5*xx st hex rev.G (current and manufactured) dimensional inspection: n/a.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Search Alerts/Recalls
|
|
|