W. L. GORE & ASSOCIATES, INC. GORE® TAG® THORACIC BRANCH ENDOPROSTHESIS; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
|
Back to Search Results |
|
| Model Number |
TAC083715A |
| Medical Device Problem Code |
Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Code |
Stroke/CVA (1770)
|
| Date of Event |
10/29/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Follow up has been requested on the status of the patient, if the patient was placed on blood thinners, if rehabilitation or therapy is required, patient medical information (medications, comorbidities, weight).As gore was unable to determine which device(s) caused or contributed to the event if any; additional device(s) implanted related to this event include the following from mpdcase-00011235-2: brand: gore® tag® thoracic branch endoprosthesis, product name: stent graft thoracic branch side branch, catalog number: tsb081206a, lot/sn: (b)(4), udi: (b)(4).Name and strength cbas® heparin surface manufacturer/compounder w.L.Gore & associates, inc.Lot number: 25292702.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
On (b)(6) 2022, the patient was reportedly admitted for treatment of a penetrating ulcer in the aortic arch and was implanted with gore® tag® thoracic branch endoprostheses.As reported, the patient underwent a carotid to subclavian artery bypass.Reportedly, this was performed to provide a landing zone for a zone 2 deployment with the side branch extending into the left subclavian artery.As reported the physician deployed the gore® tag® thoracic branch endoprosthesis aortic component without having the sheath stabilized.As reported, this made the aortic component extend further into the left subclavian than planned.As reported, the gore® tag® thoracic branch endoprosthesis branch component was loaded on the through wire before the aortic component delivery catheter was removed.As reported, this was corrected by removing both catheters.Reportedly, after visual inspection of the side branch component, there was a transition from the olive tip to the endoprosthesis.As reported, the physician then decided to open a new gore® tag® thoracic branch endoprosthesis side branch component.As reported, this was advanced up to the aortic component where there were some challenges tracking the side branch.As reported, a sheath was mated from the arm to successfully track the side branch into place.As reported after ballooning the side branch component, angiography was performed which showed no endoleak and a patent graft.Reportedly, the patient woke up without any issues after the procedure.As reported, on (b)(6) 2022, there was a change in the neurological exam.As reported, there were no previously identified neurological issues.The patient had reportedly experienced a stroke (l mca).It was reported that an mri was conducted and showed bilateral infarcts, but the location was not specified.As reported, the patient is recovering, and the source of the stroke is being investigated.Follow up has been requested on the status of the patient, if the patient was placed on blood thinners, if rehabilitation or therapy is required, patient medical information (medications, comorbidities, weight).Post-operative imaging was provided for consideration and an imaging evaluation has been issued.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: added code f24 under health effect - impact code.H6: added code a26 under medical device problem code.H6: added code g07001 under component code.H6: updating code c21 to c19.A review of the manufacturing records indicated the lot met all pre-release specifications.The imaging evaluation performed by a clinical imaging specialist showed the following: ¿ images provided are post-operative chest and head and neck cta.Mri images not available as reported.Images show the device in the aorta, the brachiocephalic, lcca and the device in the lsa are all patent.Length from the distal end of the implanted device in the lsa to the first branch measures ~ 13 mm.Unable to evaluate head ct for infarct as no device is present in the images.According to gore® tag® thoracic branch endoprosthesis instructions for use (ifu), possible adverse events and complications that may occur with the use of gore® tag® thoracic branch endoprosthesis include, but are not limited to neurologic damage, local or systemic (e.G., stroke, paraplegia, paraparesis).
|
| |
|