Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was requested, and the following was obtained via: what is the product code and lot number? i do not have the lot number for this because it was the last one in our box.I will provide all the information i do have.Product code:j207g.Sut vicryl, #0, none, 54" 12 ct.Mfr catalog #j207g, gl code 500270-00.In event description indicates "causing further complications", could you please provide more details about what complications occurred to the patient? i will add the surgical notes from the emergency clinic: vses surgical report a routine ventral midline skin incision was made extending from 1 cm caudal to the xyphoid to 1cm cranial to the pubis.Subcutaneous hemorrhage was addressed using cautery.A #15 scalpel blade was used to enter the abdomen and mayo scissors were used to extend the abdominal incision in a cranial and caudal direction.Hemorrhagic effusion was encountered upon entry into the abdomen.~600ml effusion was sterily collected in 60ml syringes and handed off to administer as an autotransfusion.An additional 400ml effusion was suctioned from the abdominal cavity.The falciform fat pad had been previously removed.Large blood clots were located in the caudal abdomen.The right testicular vessels and vas deferens were located entering into the right inguinal ring.No vessels were entering the left inguinal ring.Further exploration of the left caudal abdomen identified the transected ends of the left testicular vessels with active hemorrhage and the transected left vas deferens and associated vessels with mild oozing hemorrhage.No ligatures from neuter were identified on the left testicular pedicle vessels.The testicular vessels and vas deferens vessels were clamped and a two ligatures (proximal circumferential, distal transfixing) were placed on each.Clamps were removed and no further hemorrhage was identified.The abdomen was flushed with sterile saline to clear the remaining hemorrhagic effusion.A full abdominal explore was performed.Evaluation of the liver and diaphragm was limited by adhesions of left medial, quadrate to the ventral body wall at the sternum/diaphragm and due to the previous right sided incisional gastropexy.Palpation of the diaphragm revealed no defects and apparently healed previously performed herniorrhaphy.The gallbladder was palpable and was easily expressible, but the cbd was unable to be visualized due to previously mentioned liver adhesions.The kidneys and adrenals appeared within normal limits and were within normal size parameters.Spleen was absent, consistent with previously performed splenectomy.The bladder was small with no abnormalities noted.The stomach, duodenum, pancreas, jejunum, ileum, cecum, and colon were all within normal limits for appearance.The colon tended to be mildly displaced to the right of midline and a routine left sided colopexy was performed using 3-0 pds, simple interrupted sutures.The left testicular pedicles were again checked for hemorrhage with none noted.A sponge count was rectified prior to closure.The linea was closed using 0 pds in a simple continuous suture pattern, all air was pushed out of the abdomen prior to closure.The subcutaneous layer was closed using 3-0 monocryl with a cushing suture pattern and the skin was closed using 3-0 monocryl on a cutting needle with an intradermal pattern.Nocita injected along the incision line.
|
|
Product complaint # (b)(4).Date sent to the fda: 3/7/2023.The lot/batch was not provided; therefore, a manufacturing record evaluation could not be performed.The following additional information was obtained: there was no further information to submit as the suture box had been thrown away after surgery.The ligature slipped causing the dog to start bleeding into the abdomen where he then needed to go to an emergency clinic to stop the bleeding.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|