Model Number 28917
Medical Device Problem Code Loss of Osseointegration (2408)
Health Effect - Clinical Codes Failure of Implant (1924); Unspecified Infection (1930)
Date of Event 11/24/2022
Type of Reportable Event Serious Injury
Event or Problem Description
Implant failed due to a loss of osseointegration.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BRÅNEMARK SYSTEM MK III TIU RP 3.75X18MM
Common Device Name
ENDOSSEOUS DENTAL IMPLANT
Manufacturer (Section D)
NOBEL BIOCARE AB
dimbovägen 2
karlskoga 69151
SW  69151
MDR Report Key15881705
Report Number2027971-2022-137826
Device Sequence Number14086502
Product Code DZE
UDI-Device Identifier07332747001211
UDI-Public(01)07332747001211(10)12041348(17)200402
Combination Product (Y/N)N
Initial Reporter CountrySW
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section F) 11/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date04/02/2020
Device Model Number28917
Device Catalogue Number28917
Device Lot Number12041348
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Distributor Facility Aware Date11/28/2022
Event Location Outpatient Treatment Facility
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date11/29/2022
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age78 YR
Patient SexMale
Date Report Sent to FDA11/29/2022
-
-