• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: VYAIRE MEDICAL INC. VITAL SIGNS¿ LIMB-O¿ SINGLE LIMB ANESTHESIA BREATHING CIRCUIT; ANAESTHESIA BREATHING CIRCUIT, SINGLE-USE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

VYAIRE MEDICAL INC. VITAL SIGNS¿ LIMB-O¿ SINGLE LIMB ANESTHESIA BREATHING CIRCUIT; ANAESTHESIA BREATHING CIRCUIT, SINGLE-USE Back to Search Results
Model Number ANES CIRCUIT, ADULT, 72 IN LIMBO
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/01/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
At this time, the suspect device has not been returned for evaluation.No root cause has been determined yet.Vyaire medical will submit a supplemental report in accordance with 21 cfr section 803.56 if additional information becomes available.
 
Event or Problem Description
It was reported to vyaire medical that during surgery the afnxxxxx anes circuit, adult, 72 in limbo had a leak from the tube.The customer confirmed that the tube was changed immediately and that the reported event did not harm the patient.
 
Additional Manufacturer Narrative
Device evaluation:g3,g6,h2, h3, h6 and h10.Result of investigation:the suspect device and photo was visually inspected by quality personnel from assembly area according to pqas afm1qxxx etal and it was observed that the clear tube part number r5014a came broken, that causing the leak issue.Additionally, it was found that the circuits came without the elbow part number r5600eb.Therefore, the defect reported by the customer was confirmed.Vyaire medical will submit a supplemental report in accordance with 21 cfr section 803.56 if additional information becomes available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITAL SIGNS¿ LIMB-O¿ SINGLE LIMB ANESTHESIA BREATHING CIRCUIT
Common Device Name
ANAESTHESIA BREATHING CIRCUIT, SINGLE-USE
Manufacturer (Section D)
VYAIRE MEDICAL INC.
26125 north riverwoods blvd me
mettawa IL 60045
Manufacturer (Section G)
PRODUCTOS UROLOGOS DE MEXICO S.A. DE C.V.
cerrada vía de la producción n
o. 85, parque undustrial mexic
mexicali 21397
MX   21397
Manufacturer Contact
erika bonilla
510 technology drive
irvine, CA 92618
MDR Report Key15886758
Report Number3013421741-2022-00025
Device Sequence Number5122739
Product Code CAI
UDI-Device Identifier10190752122239
UDI-Public(01)10190752122239(10)0004210125
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/30/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberANES CIRCUIT, ADULT, 72 IN LIMBO
Device Catalogue NumberAFNXXXXX
Device Lot Number0004210125
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/02/2022
Supplement Date Received by Manufacturer11/02/2022
Initial Report FDA Received Date11/30/2022
Supplement Report FDA Received Date01/05/2023
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-