Model Number M00546600
Medical Device Problem Codes Poor Quality Image (1408); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/01/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported to boston scientific corporation that a spyscope ds was used during an intrahepatic bile duct probing procedure performed on (b)(6) 2022.During procedure, the spyscope ds screen flickered severely and could no longer used.The procedure was not completed due to this event.The patient's condition was reported to be stable.
 
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported to boston scientific corporation that a spyscope ds was used during an intrahepatic bile duct probing procedure performed on (b)(6) 2022.During procedure, the spyscope ds screen flickered severely and could no longer used.The procedure was not completed due to this event.The patient's condition was reported to be stable.
 
Additional Manufacturer Narrative
Block h6 (impact codes): impact code f1001 is being used to capture the reportable event of aborted/cancelled procedure.Block h10: the returned spyscope ds ii was analyzed, and a visual evaluation was performed.Elevator marks were noted on the shaft of the catheter.Upon plugging the device into the controller, no live image was seen.The device was fully articulated in all directions.There was no impact to the image was seen.X-ray imaging of the distal tip showed no problems with the redistribution layer (rdl).Potential camera wire damage was observed near the distal end in the form of a break.No camera wire damage was observed in the pebax region of the catheter.X-ray imaging of the handle showed no problems with the printed circuit board assembly (pcba) or camera wire damage in the handle and around the strain relief.The handle was opened and the electrical components inside were inspected visually.There was procedural residue seen in the plastic optic fibers (pof).Visual assessment showed no problems with the camera wires near the pcba.The bond of the glue feature to the pcba was inspected; tweezers were used to wiggle the glue feature.The connection of the camera wires to the pcba was also inspected by slightly lifting the bottom of the glue feature for each of the four camera wires using the tip of the tweezers.No impact to image was seen after these interactions.The reported complaint was confirmed.During product analysis, the condition of the wires suggests a lack of controls regarding camera wire handling during the manufacturing process (likely during camera/pof potting, stuffing, and/or pof bonding), resulting in nicked insulation of the camera wires and twisting of wires.Process controls were implemented on the manufacturing line to minimize the occurrence of this failure.This included additional visual inspections and new tooling that had less blunt edges that could nick the insulation of the camera wire.It is likely that the damage to the camera wire, as well as handling of the device during procedure, created a break in connection of the camera during the procedure, which then caused the reported visualization issue.Based on all gathered information, the probable cause for the visualization issue due to distal camera wire damage is manufacturing deficiency, which indicates that problems were traced to the manufacturing process.A labeling review was performed and, from the information available, this device was used per the instructions for use (ifu) / product label.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPYSCOPE DS
Common Device Name
CHOLEDOCHOSCOPE AND ACCESSORIES, FLEXIBLE/RIGID
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
780 brookside drive
spencer IN 47460
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key15924017
Report Number3005099803-2022-07175
Device Sequence Number5218524
Product Code FBN
UDI-Device Identifier08714729863236
UDI-Public08714729863236
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K142922
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/01/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/24/2024
Device Model NumberM00546600
Device Catalogue Number4660
Device Lot Number0029824328
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/18/2022
Supplement Date Received by Manufacturer01/06/2023
Initial Report FDA Received Date12/06/2022
Supplement Report FDA Received Date02/01/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/25/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age57 YR
Patient SexMale
Patient Weight70 KG
-
-