Customer is going to return product # 2700ql due to complaint.Customer stated patient broke out of tat restraints due to broken buckle.No explanation on how the buckle broke.Product # 2700ql with lot# 1288t070.
 
Additional Manufacturer Narrative
Product is scheduled to be returned but has not been received in by manufacturing site at the time of this report.Therefore, this report is based solely on the information provided by the customer.Customer confirmed the patient was combative and fighting against the restraints.The buckle of the wrist restraint broke and patient was trying to undo velcro with force.The instructions for use contraindications state do not use this device with someone who has continued highly aggressive or combative behavior, self-destructive behavior, or deemed to be an immediate risk to others or to self.Clinicians may need to use additional interventions in conjunction with restraints.At this time there is no evidence that a manufacturing non-conformity contributed to the reported complaint, and the instructions for use were reviewed and determined to provide adequate instructions and warnings for the safe and effective use of the device.All complaints are trended and reviewed by management on a monthly basis.As part of this monthly review, any excursion above the control limits for this failure mode will be assessed, documented and acted upon as warranted.Manufacturer reference file (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNIVERSAL TWICE-AS-TOUGH QUICK RELEASE CUFF, LARGE
Common Device Name
RESTRAINT, PROTECTIVE
Manufacturer (Section D)
TIDI PRODUCTS
570 enterprise drive
neenah WI 54956
Manufacturer Contact
chris rahn
570 enterprise drive
neenah, WI 54956
9207514300
MDR Report Key15932428
Report Number2182318-2022-00137
Device Sequence Number4396992
Product Code FMQ
UDI-Device Identifier10190676002808
UDI-Public10190676002808
Combination Product (Y/N)N
Initial Reporter StateSC
Initial Reporter CountryUS
PMA/510(K) Number
K963413
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 11/08/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number2700QL
Device Catalogue Number2700QL
Device Lot Number1228T070
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/08/2022
Initial Report FDA Received Date12/07/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-