| Model Number |
AR40E |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/14/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
If implanted, give date: unknown/not provided.If explanted, give date: unknown/not provided.Telephone number: (b)(6).The device is not returned; therefore, a failure analysis of the complaint device cannot be completed.A review of the device record and complaint trending for this device will be performed.Upon completion of the review, if there is any further relevant information a supplemental medwatch will be filed.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Event or Problem Description
|
|
It was reported that there are two techno vigilance notifications.In both cases, the supplier collects the materials and sends them to the manufacturer for analysis, after the analysis we receive the feedback.If it is found that there really was a manufacturing defect, the supplier sends a return note referring to the supplies, generating a credit for the hospital, "lens with a crack".No other information was provided.This report captures event for suspect product ar40e, serial number (b)(4).The other suspect product mentioned will be captured in a separate report.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: section a2, age - 83, section a2, date of birth - (b)(6) 1939, section a3, gender - male, customer also reported that the intraocular lens (iol) was fully inserted.It required a removal and replacement due to the lens being damaged.There was a delay in treatment.The incision was enlarged.Sutures were required and medication was prescribed.Patient's initials: (b)(6), affected eye: left eye, all pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
On 27-feb-2023, the following additional information was received: section a5: ethnicity, patient is latino but not hispanic.Section a5: race, white.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: section d9.Device available for evaluation? yes.Returned to manufacturer on dec 04, 2023.Section h3.Device evaluated by manufacturer? yes.Device evaluation: the product was returned to the manufacturing site for evaluation.Visual inspection reveal that the complaint lens was observed to be coated in viscoelastic residue.The lens was cleaned, and damage on the surface and edges of the lens were observed.The lens was torn in the haptic region of the lens separating the haptic from the lens; the other haptic was damaged.The complaint issue "lens damaged" was identified during product evaluation.However, based on the complaint investigation results the complaint issue could not be confirmed to be related to the manufacturing or design process.Conclusion: as a result of the investigation there is no indication of a product quality deficiency and the reported issue could not be verified.All pertinent information available to johnson & johnson surgical vision, inc has been submitted.
|
| |
|