• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ROCHE DIAGNOSTICS COBAS INFINITY CORE SOFTWARE; CALCULATOR/DATA PROCESSING MODULE, FOR CLINICAL USE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ROCHE DIAGNOSTICS COBAS INFINITY CORE SOFTWARE; CALCULATOR/DATA PROCESSING MODULE, FOR CLINICAL USE Back to Search Results
Catalog Number 07154003001
Medical Device Problem Codes Computer Software Problem (1112); Application Program Problem (2880)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/18/2022
Type of Reportable Event Malfunction
Event or Problem Description
The initial reporter stated they have an issue with the cobas infinity software using with cobas infinity microbiology lab module s, serial number 48003619om4mi.There was a mismatch of the antibiogram results between the reports from two different patients that were generated using an external webservice.The customer provided an example of a questionable report versus the expected report for one patient: the questionable report contained the following information: amoxicilina-clavulanico = s, ampicilina/amoxicilina = r, piperacilina-tazobactam = no result provided, meropenem = no result provided, cefuroxima = s, ceftazidima = no result provided, cefepime = no result provided, norfloxacino = s, ciprofloxacino = s, tobramicina = no result provided, cortrimoxazol = s, fosfomicina = s, furantoina = s.The expected report contained the following information: piperacilina-tazobactam = s, meropenem = s, ceftazidima = s, cefepime = s, ciprofloxacino = r, tobramicina = s.
 
Additional Manufacturer Narrative
The investigation identified the root of the reported allegation at the code level.When assigning printable antibiotics to a report, the order number to which they belong is not taken into account.So, if antibiotics from different orders are processed in a short period of time, they are assigned to the same order.The reported allegation has been verified as a software issue in cobas infinity, as the system should not add antibiogram results from other orders to a report from a given order.There was no report of any patient harm due to this issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COBAS INFINITY CORE SOFTWARE
Common Device Name
CALCULATOR/DATA PROCESSING MODULE, FOR CLINICAL USE
Manufacturer (Section D)
ROCHE DIAGNOSTICS
9115 hague road
indianapolis IN 46250 0457
Manufacturer (Section G)
ROCHE DIAGNOSTICS GMBH
sandhoferstrasse 116
na
mannheim (baden-wurttemberg) 68305
GM   68305
Manufacturer Contact
amy nelson
9115 hague road
na
indianapolis, IN 46250
3174767531
MDR Report Key15959685
Report Number1823260-2022-03964
Device Sequence Number5229505
Product Code JQP
UDI-Device Identifier04015630936007
UDI-Public04015630936007
Combination Product (Y/N)N
Initial Reporter CountrySP
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 01/25/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number07154003001
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/18/2022
Supplement Date Received by Manufacturer01/02/2023
Initial Report FDA Received Date12/12/2022
Supplement Report FDA Received Date01/25/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-