MAUDE Adverse Event Report: BOSTON SCIENTIFIC NEUROMODULATION VERCISE; STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC NEUROMODULATION VERCISE; STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR Back to Search Results
Model Number DB-9218-15
Medical Device Problem Code High impedance (1291)
Health Effect - Clinical Code Inadequate Pain Relief (2388)
Date of Event 11/22/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Event date: approximated based on the date the manufacturer became aware of the event.Additional suspect medical device component involved in the event: brand name: vercise; upn: m365db9218550; model: db-9218-55; serial: no information; batch: no information.
 
Event or Problem Description
It was reported that high impedances were noted on the m8 adapters after the patient underwent an unrelated procedure.The patient underwent a procedure in which the ipg pocket was opened and the m8 adapters were replaced.The high impedances resolved and the patient is doing well post operatively.
 
Event or Problem Description
It was reported that high impedances were noted on the m8 lead adapters after the patient underwent non-device related procedure.The patient underwent a revision procedure where the m8 lead adapters were replaced.The high impedances resolved and the patient is doing well postoperatively.It was additionally reported that the two contacts that came off of the device did so during the extraction process.The physician confirmed the contacts were removed from the patient's body and were disposed of.
 
Additional Manufacturer Narrative
Block b3: approximated based on the date the manufacturer became aware of the event.Additional suspect medical device component involved in the event: brand name: vercise, upn: m365db9218550, model: db-9218-15, serial: (b)(6), batch: 7072849.Db-9218-55; 7072858: visual inspection revealed that the top two contacts are separated from the proximal end.X-ray inspection of the m8 lead adapter revealed that cable 2 was fractured and pulled after the weld in the distal connector stack.Contacts 1 and 2 were not returned.It appears that excessive tensile force was exerted on the top two contacts resulting in the separation.Excessive tensile force also caused the cables to be pulled between contacts 3 to 8; the cables are exposed at the fracture location.It is unlikely for the adapter proximal end to be damaged while it is implanted and inserted into an implantable pulse generator (ipg) port as the proximal array is well protected within the ipg port.The damage is a result of a typical explant procedure, and it is not considered a failure.No other anomalies were identified aside from the 2 damaged proximal contacts.Db-9218-55; 7072849: the m8 lead adapter was returned, analyzed, passed all tests performed, and exhibited normal device characteristics.A labeling review was performed, and it did not reveal any anomalies.The instructions for use (ifu) states that failure or malfunction of any of the device components or the battery, including but not limited to lead or extension breakage, hardware malfunctions, loose connections, electrical shorts or open circuits and lead insulation breaches, and loss of adequate stimulation are known risks with the use of deep brain stimulation.Based on available information, a review of the manufacturing documentation for the m8 lead adapters confirmed that the devices passed all required specifications and testing prior to being released for distribution/sale.A labeling review which indicated that the events of high impedance and the patient not receiving relief are known risks associated with the use of dbs.The returned devices were analyzed and no problems were found, however engineers determined that contacts on one of the lead adapters were likely damaged during the explant procedure and is not considered a failure.Therefore, no problem was detected.
 
Additional Manufacturer Narrative
Block b3: approximated based on the date the manufacturer became aware of the event.Additional suspect medical device component involved in the event: brand name: vercise.Upn: m365db9218550.Model: db-9218-55.Serial: (b)(4).Batch: 7072849.Device technical analysis: db-9218-55; 7072858: visual inspection revealed that the top two contacts are separated from the proximal end, x-ray inspection of the m8 adapters revealed that cable 2 was fractured after the weld in the distal connector stack and was also pulled, contacts 1 and 2 were not returned.It appears that excessive tensile force was exerted on the top two contacts resulting in its separation and cables to be pulled between contacts 3 to 8, and are exposed at the fracture location.It is unlikely for the adapter proximal end to be damaged while it is implanted and inserted into an ipg port as the proximal array is well protected within the ipg port.The damage is a result of a typical explant procedure, and it is not considered a failure.No other anomalies were identified aside from the 2 damaged proximal contacts.Db-9218-55; 7072849: the m8 adapter was returned and analyzed, no anomalies were found.Labeling review: a labeling review was performed on the devices instructions for use, ifu, and it did not reveal any anomalies as it states that failure or malfunction of any of the device components or the battery, including but not limited to lead or extension breakage, hardware malfunctions, loose connections, electrical shorts or open circuits and lead insulation breaches, whether or not this requires explant and/or re-implantation and loss of adequate stimulation are known risks with the use of deep brain stimulation.Investigation conclusion: based on all available information, engineers are not able to confirm the root cause of the event.The m8 adapters were returned and analyzed, as such physical analysis was conducted, record review revealed no additional information related to the complaint.Therefore, this investigation concludes that no problem was detected.
 
Event or Problem Description
It was reported that high impedances were noted on the m8 adapters after the patient underwent an unrelated procedure.The patient underwent a procedure in which the ipg pocket was opened and the m8 adapters were replaced.The high impedances resolved and the patient is doing well post operatively.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VERCISE
Common Device Name
STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR
Manufacturer (Section D)
BOSTON SCIENTIFIC NEUROMODULATION
25155 rye canyon loop
valencia CA 91355
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
erik sherburne sherburne
25155 rye canyon loop
valencia, CA 91355
7632920920
MDR Report Key15966752
Report Number3006630150-2022-06962
Device Sequence Number20061743
Product Code MHY
UDI-Device Identifier08714729905196
UDI-Public08714729905196
Combination Product (Y/N)N
Initial Reporter CountrySW
PMA/510(K) Number
P150031
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 03/13/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/22/2023
Device Model NumberDB-9218-15
Device Catalogue NumberDB-9218-15
Device Lot Number7072858
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/29/2022
Supplement Date Received by Manufacturer02/02/2023
02/28/2023
Initial Report FDA Received Date12/13/2022
Supplement Report FDA Received Date02/25/2023
03/13/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/22/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-