Model Number 6720127105
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/17/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that during a femoral and tibial osteotomy procedure, the blade broke.No further information was provided at this time.
 
Additional Manufacturer Narrative
A follow up report will be filed once the quality investigation is complete.Awaiting confirmation if device is available for return.
 
Additional Manufacturer Narrative
H6: the quality investigation is complete.H3 other text : device not returned.
 
Event or Problem Description
It was reported that during a femoral and tibial osteotomy procedure, the blade broke.It was subsequently reported that the saw blade was stuck inside the patient's bone and was successfully retrieved with no adverse consequences.It was further reported that there was a ten minute delay as a result of this event.
 
Event or Problem Description
It was reported that during a femoral and tibial osteotomy procedure, the blade broke.It was subsequently reported that the saw blade was stuck inside the patient's bone and was successfully retrieved with no adverse consequences.It was further reported that there was a ten minute delay as a result of this event.
 
Additional Manufacturer Narrative
B5: updated based on new information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRECISION FALCON OSCILLATING TIP SAW CARTRIDGE (20 X 1.27 X 105MM)
Common Device Name
INSTRUMENT, SURGICAL, ORTHOPAEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT
Manufacturer (Section D)
STRYKER INSTRUMENTS-A DIVISION OF STRYKER CORP
1941 stryker way
portage MI 49002
Manufacturer (Section G)
STRYKER INSTRUMENTS-IRELAND
instruments division
carrigtwohill bus. & tech park
carrigtwohill NA
EI   NA
Manufacturer Contact
una barry
instruments division
carrigtwohill bus. & tech park
carrigtwohill NA
EI   NA
214532900
MDR Report Key15968040
Report Number3015967359-2022-02438
Device Sequence Number14729343
Product Code HWE
UDI-Device Identifier07613327143737
UDI-Public07613327143737
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/17/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number6720127105
Device Catalogue Number6720127105
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 11/17/2022
Supplement Date Received by Manufacturer01/05/2023
01/11/2023
Initial Report FDA Received Date12/13/2022
Supplement Report FDA Received Date01/05/2023
01/17/2023
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;