| Model Number |
N/A |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); Joint Laxity (4526); Swelling/ Edema (4577)
|
| Date of Event |
01/10/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).The device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001822565-2022-03473; 0001822565-2022-03474; 0001822565-2022-03475; 0001822565-2022-03476; 0001822565-2022-03477; 0001822565-2022-03478; 0001822565-2022-03479; 0001822565-2022-03481; 0001822565-2022-03483; 0001822565-2022-03484.
|
| |
|
Event or Problem Description
|
|
It was reported a patient underwent an initial left knee arthroplasty with unknown product.The patient was revised approximately 1.5 years later due to implant loosening.At the 1 year follow up, the patient presented with left lateral knee pain that radiates to lower leg.Narcotics were prescribed.At the 2 year follow up appointment.A large left knee effusion was present.Left knee aspiration was completed in the office.No further complications reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.An investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient underwent a total knee arthroplasty.At the 1 year follow up, the patient presented with left lateral knee pain that radiates to lower leg.Narcotics were prescribed.At the 2 year follow up appointment, a large left knee effusion, tibial radiolucency, and laxity was present.Left knee aspiration was completed in the office.No further complications reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated: b4; b5; g3; g6; h1; h2; h3; h6; h10 no product was returned or pictures provided; visual and dimensional evaluations could not be performed.The device history record was reviewed and no discrepancies relevant to the reported event were found.Medical records/radiographs were provided and reviewed by a health care professional.Review of the available records identified moderate pain with some effusion but no instability.X-ray found tibial radiolucency.A definitive root cause cannot be determined.Per package insert: pain, swelling are known adverse effect of the system.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated: b3; b4; b5; d6b; g3; g6; h1; h2; h6 an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient underwent a total knee arthroplasty.At the 1 year follow up, the patient presented with left lateral knee pain that radiates to lower leg.Narcotics were prescribed.At the 2 year follow up appointment, a large left knee effusion was present.Left knee aspiration was completed in the office.Approximately 34 months post implantation, the patient underwent a left knee revision.The articular surface was replaced.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.Medical records were provided and reviewed by a health care professional.Review of the available records identified the following: pain, full rom, x-rays show lucency under tibial plate, large effusion and laxity noted, instability.Radiographs were not sent out for review as they were covered in the medical records.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further information at the time of this report.
|
| |
|