Model Number IPN915328
Medical Device Problem Code Difficult to Open or Remove Packaging Material (2922)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/02/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Qn#(b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
 
Event or Problem Description
Reported issue: during treatment for cardiogenic shock, at about 17:00 on november 2 when the iab catheter in the left femoral artery, was removed from the patient, it was found that the balloon was very hard to pull back into the arterial sheath, and after pulling for a while, it could not be pulled, and the balloon could not enter the sheath.It was pulled out together with the sheath and balloon without resistance, and the patient was well with no blood leakage.The patient's condition was reported as fine.
 
Event or Problem Description
Reported issue: during treatment for cardiogenic shock, at about 17:00 on november 2 when the iab catheter in the left femoral artery, was removed from the patient, it was found that the balloon was very hard to pull back into the arterial sheath, and after pulling for a while, it could not be pulled, and the balloon could not enter the sheath.It was pulled out together with the sheath and balloon without resistance, and the patient was well with no blood leakage.The patient's condition was reported as fine.
 
Additional Manufacturer Narrative
(b)(4).Complaint verification testing could not be performed as no sample was returned for analysis.A device history record review was performed, and no relevant findings were identified.Without the device to evaluate, the complaint could not be confirmed, and the probable cause could not be determined from the available information.Teleflex will continue to monitor and trend for reports of this nature.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REDIGUARD IAB: 8FR 40CC
Common Device Name
SYSTEM, BALLOON, INTRA-AORTIC
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL INC.
16 elizabeth drive
chelmsford MA 01824
Manufacturer Contact
bryanna connelly
3015 carrington mill blvd
morrisville 27560
9194332672
MDR Report Key15982568
Report Number3010532612-2022-00544
Device Sequence Number20572890
Product Code DSP
UDI-Device Identifier10801902162004
UDI-Public20801902162001
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K981660
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 11/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2024
Device Model NumberIPN915328
Device Catalogue NumberIAB-S840C
Device Lot Number18F22D0044
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/22/2022
Supplement Date Received by Manufacturer01/11/2023
Initial Report FDA Received Date12/14/2022
Supplement Report FDA Received Date01/11/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured04/25/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NONE REPORTED; NONE REPORTED
Patient Age74 YR
Patient SexMale
-
-