ZIMMER ORTHOPAEDIC MFG. LTD. NATURAL TIBIA CEMENTED 5 DEGREE STEMMED LEFT SIZE E; PROSTHESIS, KNEE Back to Search Results
Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Pneumonia (2011)
Date of Event 05/22/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Report source: foreign - new zealand.The device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 3007963827-2022-00326, 0002648920-2022-00254.
 
Event or Problem Description
It was reported that the patient underwent a right total knee arthroplasty.The same day, the patient was diagnosed with bilateral lower lobe pneumonia through chest x-ray.The patient was placed on augmentin for 7 days.The pneumonia resolved 3 weeks later without further complication.Attempts have been made and no further information has been provided.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Procedural related complications are influenced by the type of surgery, patients pre-existing comorbidities, and perioperative management.Pneumonia is a well-known postoperative complication that typically requires medical intervention and possibly even hospitalization for more aggressive medical management.Within a two-hour postoperative window, the protective reflexes of the oropharyngeal passages are depressed, and the patient can aspirate.The reason for postoperative pneumonia is typically due to aspiration of subglottic secretions containing bacteria.Once the bacteria enter the respiratory tract, they can replicate and advance into aspiration pneumonia.Patient that have known history of respiratory or lung diseases such as copd, asthma, or are immune suppressed are at increased risk for developing this complication.Pneumonia is a procedural related complication resulting from intubation during the procedure and is considered a hospital-acquired condition.As the complaint indicates, a postoperative complication of pneumonia developed, and medical intervention was required for treatment.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NATURAL TIBIA CEMENTED 5 DEGREE STEMMED LEFT SIZE E
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER ORTHOPAEDIC MFG. LTD.
building no 2 east park
shannon industrial estate
shannon, county clare
EI 
Manufacturer (Section G)
ZIMMER ORTHOPAEDIC MFG. LTD.
building no 2 east park
shannon industrial estate
shannon, county clare
EI  
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key15990533
Report Number3007963827-2022-00327
Device Sequence Number5724297
Product Code JWH
UDI-Device Identifier00889024471054
UDI-Public(01)00889024471054(17)261130(10)63490896
Combination Product (Y/N)N
Initial Reporter CountryNZ
PMA/510(K) Number
K113369
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Study,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/06/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number42532007101
Device Lot Number63490896
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/25/2022
Supplement Date Received by Manufacturer01/05/2023
Initial Report FDA Received Date12/15/2022
Supplement Report FDA Received Date01/06/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/05/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexFemale
Patient Weight123 KG
-
-