| Model Number |
H74939406XS1 |
| Medical Device Problem Code |
Material Split, Cut or Torn (4008)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
This medwatch report is being filed based on the review of an image provided on (b)(6) 2022.The actual device was not received at the time of this report; therefore, no physical analysis of the device can be performed.A review of the device history records of the specimen device does not present any indication of manufacturing defect or anomaly that could have impacted on the event as reported.During manufacturing and packaging of this product the operators are instructed to 100% visually inspect for any obvious defect prior to shipment.The history records indicate this product was final inspection tested at lake region medical and was determined to be acceptable.As described in the device instructions for use (dfu): 1.Ensure a catheter is properly placed in the ventricle or other intended treatment area.2.Carefully remove the safari2tm guidewire from the hoop by grasping the proximal end of the j-straightener separating the straightener from the hoop.3.After inspection of the safari2tm guidewire, advance the j-straightener over the distal section of the safari2tm guidewire to straighten the curve.4.Insert the safari2tm guidewire into the hub of the catheter with the aid of the j-straightener.5.Carefully advance the distal tip of the safari2tm guidewire into the lumen of the catheter.6.Remove the safari2tm guidewire j-straightener by withdrawing it over the length of the safari2tm guidewire.7.Advance the safari2tm guidewire through the catheter under fluoroscopic guidance the customer supplied image presented a fracture of the core wire and stretched coil wraps in the distal tip extending proximally from the j-straightener/introducer.At this time, it is not possible to assign a definitive root cause for the event as reported.Based on the information provided to date, it appears that clinical and/or handling factors may have impacted on the event as reported.The patient information and event date were not provided at the time of this report.If any further relevant information is provided, a follow up medwatch report will be submitted.
|
| |
|
Event or Problem Description
|
|
Event description: : during the case, the safari wire became frayed, the procedure was completed and the wire was removed in its entirety.What is the next course of action?: finished the case.Patient present at time of event?: yes.Patient complications: no patient complications.Procedure date: unknown.Additional information received december 14, 2022: the wire never entered the patient's body, when they pulled the wire out of the coil, the wire was frayed.
|
| |
|
Search Alerts/Recalls
|