Model Number DBP-EX-200SOL145
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/17/2022
Type of Reportable Event Serious Injury
Event or Problem Description
A diamondback 360 exchangeable orbital atherectomy device (oad) was used to treat the superficial femoral artery (sfa).A treatment was performed on low speed, however, the crown was not moving even with the control knob being moved.It was observed that the driveshaft was fractured.The physician suspected the crown was entrapped in the sfa.Additional pedal access was obtained to attempt to free the crown.Upon further review of the imaging, it was determined the driveshaft could likely be removed by pulling back the guidewire.The oad and wire were successfully removed.A new oad was used to complete the procedure.The patient was stable.
 
Additional Manufacturer Narrative
The oad was returned to csi for analysis which confirmed that the driveshaft had separated.The separation of the driveshaft was located at the handle assembly where it cannot enter in the patient and therefore would not cause or contribute to serious injury or death.The cause of the additional intervention during the procedure could not be conclusively determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DIAMONDBACK 360 PERIPHERAL ORBITAL ATHERECTOMY SYSTEM
Common Device Name
PERIPHERAL ATHERECTOMY DEVICE
Manufacturer (Section D)
CARDIOVASCULAR SYSTEMS, INC.
1225 old hwy 8 nw
st. paul MN 55112
Manufacturer (Section G)
CARDIOVASCULAR SYSTEMS, INC.
1225 old hwy 8 nw
st. paul MN 55112
Manufacturer Contact
tonia moskalets
1225 old hwy 8 nw
st. paul, MN 55112
MDR Report Key16000135
Report Number3004742232-2022-00317
Device Sequence Number12167423
Product Code MCW
UDI-Device Identifier10852528005848
UDI-Public(01)10852528005848(17)241031(10)456605
Combination Product (Y/N)N
Initial Reporter StateOK
Initial Reporter CountryUS
PMA/510(K) Number
K190634
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 12/16/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date10/31/2024
Device Model NumberDBP-EX-200SOL145
Device Catalogue Number7-10030-04
Device Lot Number456605
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/30/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/17/2022
Initial Report FDA Received Date12/16/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/10/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age62 YR
Patient SexMale
Patient Weight136 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-