Model Number M0062251080
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/18/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported to boston scientific corporation that a uromax ultra dilatation balloon catheter was used in the right ureter during an ureteroscopy (urs) procedure performed on (b)(6) 2022.During the procedure, it was noticed that the balloon was leaking contrast.The procedure was completed with another uromax ultra dilatation balloon catheter.There were no patient complications reported as a result of this event.
 
Additional Manufacturer Narrative
Block h6: imdrf device code a0504 captures the reportable event of balloon leak.Block h10: investigation result: the returned uromax ultra balloon was analyzed, and a visual evaluation noted that the balloon was not folded which indicates that the balloon was subjected to positive pressure.The device was returned attached to an encore inflation unit.Functional evaluation was performed by applying positive pressure, and it was observed that the balloon was leaking due to a pinhole located at the proximal of the distal markerband.A visual and tactile examination revealed that there were no problems found on the shaft and the tip of the device.A visual examination was also performed to the markerbands, and no problems were observed.Additionally, both markerbands are in the correct position on the shaft of the device.No other problems with the device were noted.The reported event of balloon leak was confirmed.It is possible that the interaction between the balloon and ureteral stone could have caused the pinhole found in the balloon material.Taking all available information into consideration, the most probable cause of this complaint is adverse event related to procedure because the adverse event occurred during the procedure and the device had no influence on the event.A labeling review was performed and from the information available, this device was used per the instructions for use (ifu)/product label.
 
Event or Problem Description
It was reported to boston scientific corporation that a uromax ultra dilatation balloon catheter was used in the right ureter during an ureteroscopy (urs) procedure performed on (b)(6) 2022.During the procedure, it was noticed that the balloon was leaking contrast.The procedure was completed with another uromax ultra dilatation balloon catheter.There were no patient complications reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UROMAX ULTRA
Common Device Name
DILATOR, CATHETER, URETERAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key16003424
Report Number3005099803-2022-07430
Device Sequence Number6577828
Product Code KOE
UDI-Device Identifier08714729341185
UDI-Public08714729341185
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
K130804
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/30/2024
Device Model NumberM0062251080
Device Catalogue Number225-108
Device Lot Number0028299913
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/21/2022
Supplement Date Received by Manufacturer01/26/2023
Initial Report FDA Received Date12/19/2022
Supplement Report FDA Received Date02/21/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/31/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexMale
-
-