Model Number 15
Medical Device Problem Codes Defibrillation/Stimulation Problem (1573); Unexpected Shutdown (4019)
Health Effect - Clinical Codes Bradycardia (1751); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/07/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The customer provided stryker with all the available patient information.Patient fields in which information was not provided were intentionally left blank.Stryker continues to investigate the reported issue and will submit a supplemental report on this event to the fda as provided by 21 cfr 803.56.
 
Event or Problem Description
The customer contacted stryker to report that their device powered off by itself when performed cardioversion on a patient.A different defibrillator was used to complete the procedure.In addition it was reported the device logged a critical event code.The event code is related to a potential issue of the device to deliver energy.In this state, defibrillation therapy may be delayed or not available if needed.This issue is patient related; however, there was no adverse patient outcome reported.
 
Additional Manufacturer Narrative
Stryker evaluated the customer¿s device and was unable to duplicate or verify the reported issue power issue.The reported event code issue was verified, however the code was not repeatable.After observing proper device operation through functional and performance testing the device was returned to the customer for use.The cause of the reported issues could not be conclusively determined.
 
Event or Problem Description
The customer contacted stryker to report that their device powered off by itself when performed cardioversion on a patient.A different defibrillator was used to complete the procedure.In addition it was reported the device logged a critical event code.The event code is related to a potential issue of the device to deliver energy.In this state, defibrillation therapy may be delayed or not available if needed.This issue is patient related; however, there was no adverse patient outcome reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LIFEPAK(R) 15 MONITOR/DEFIBRILLATOR
Common Device Name
AUTOMATED EXTERNAL DEFIBRILLATORS (NON-WEARABLE)
Manufacturer (Section D)
PHYSIO-CONTROL, INC. - 3015876
11811 willows road ne
redmond WA 98052
Manufacturer (Section G)
PHYSIO-CONTROL, INC. - 3015876
11811 willows road ne
redmond WA 98052
Manufacturer Contact
todd bandy
11811 willows road ne
redmond, WA 98052
4258674000
MDR Report Key16011035
Report Number0003015876-2022-02727
Device Sequence Number7303505
Product Code MKJ
UDI-Device Identifier00883873871676
UDI-Public00883873871676
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
P160026
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 03/07/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number15
Device Catalogue Number99577-001959
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/19/2022
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/07/2022
Supplement Date Received by Manufacturer03/06/2023
Initial Report FDA Received Date12/19/2022
Supplement Report FDA Received Date03/07/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/26/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-