MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE; DEVICE IMPOTENCE MECHANICAL/HYDRAULIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE; DEVICE IMPOTENCE MECHANICAL/HYDRAULIC Back to Search Results
Model Number 72404262
Medical Device Problem Codes Mechanical Problem (1384); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Pain (1994)
Date of Event 12/06/2022
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the patient underwent a surgical procedure to explant this inflatable penile prosthesis (ipp) due to the left cylinder pushing laterally on the skin in addition to pain in the glans at the cylinder tip.The existing device was removed and replaced with a new ipp.No further patient complications were reported.
 
Additional Manufacturer Narrative
Upon receipt at our post market quality assurance laboratory, the ams700 inflatable penile prosthesis (ipp) was visually inspected, leak tested and examined using a microscope.Both cylinders had wear at folds in the middle and proximal cylinder bodies and the kink resistant tubing (krt) of both cylinders was worn down to the filament.No leaks were found.Inspection of the momentary squeeze (ms) pump noted the krt was worn down to the filament.Again, no leaks were identified.The pump krt with window quick connector was trimmed down to the appropriate length prior to functional testing.The pump did not pass the inflation test.Product analysis concluded these inflation issues could affect the functionality of the device as reported mechanical issues.Product analysis confirmed pump malfunction but was unable to confirm the reported event related to the pain.
 
Event or Problem Description
It was reported that the patient underwent a surgical procedure to explant this inflatable penile prosthesis (ipp) due to the left cylinder pushing laterally on the skin in addition to pain in the glans at the cylinder tip.The existing device was removed and replaced with a new ipp.No further patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMS INFLATABLE PENILE PROSTHESIS WITH INHIBIZONE
Common Device Name
DEVICE IMPOTENCE MECHANICAL/HYDRAULIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
alyson harris
4100 hamline avenue north
building c
saint paul, MN 55112
MDR Report Key16016928
Report Number2124215-2022-53873
Device Sequence Number17827040
Product Code FHW
UDI-Device Identifier00878953003702
UDI-Public00878953003702
Combination Product (Y/N)Y
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
N970012
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 01/30/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date01/12/2017
Device Model Number72404262
Device Catalogue Number72404262
Device Lot Number915942005
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/08/2022
Supplement Date Received by Manufacturer01/30/2023
Initial Report FDA Received Date12/20/2022
Supplement Report FDA Received Date01/30/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/27/2015
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age73 YR
Patient SexUnknown
-
-