• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDIVANCE, INC. ¿ 1725056 ARCTIC SUN® TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL¿ PADS; ARCTICGEL PADS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDIVANCE, INC. ¿ 1725056 ARCTIC SUN® TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL¿ PADS; ARCTICGEL PADS Back to Search Results
Model Number 31801
Medical Device Problem Code Device Handling Problem (3265)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/28/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
 
Event or Problem Description
It was reported that the patient currently on arctic sun device with one small universal pad connected.Weight of patient was too small for xxs pads which was the smallest size they currently have.Patient has been on therapy for 5 days now.It was maintaining temperature and cooling the patient, but the last 2 days patient did not seem to be cooling.Patient weight 12 kilograms.Been alerting low flow.Mis explained for patient weight recommended pad application would be 3 small universal pads.Wrap 2 pads loosely around chest and abdomen.Add a third pad around the legs.Nurse stated they have no more universal small pads.Flow rate was 0.4 lpm.Mis discussed importance of flow rate for functionality.Nurse has a set of xxs arctic gel pads nurse would connect to boost flow rate.Emailed pediatric pad size qrgs.
 
Event or Problem Description
It was reported that the patient currently on arctic sun device with one small universal pad connected.Weight of patient was too small for xxs pads which was the smallest size they currently have.Patient has been on therapy for 5 days now.It was maintaining temperature and cooling the patient, but the last 2 days patient did not seem to be cooling.Patient weight 12 kilograms.Been alerting low flow.Mis explained for patient weight recommended pad application would be 3 small universal pads.Wrap 2 pads loosely around chest and abdomen.Add a third pad around the legs.Nurse stated they have no more universal small pads.Flow rate was 0.4 lpm.Mis discussed importance of flow rate for functionality.Nurse has a set of xxs arctic gel pads nurse would connect to boost flow rate.Emailed pediatric pad size qrgs.
 
Additional Manufacturer Narrative
Upon further review, bd has determined that this mdr is not reportable.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTIC SUN® TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL¿ PADS
Common Device Name
ARCTICGEL PADS
Manufacturer (Section D)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
suite 200
louisville 80027
Manufacturer (Section G)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
suite 200
louisville 80027
Manufacturer Contact
xeeroy rada
8195 industrial blvd
covington 30014
7707846100
MDR Report Key16029274
Report Number1018233-2022-09761
Device Sequence Number20244622
Product Code DWJ
UDI-Device Identifier00801741080128
UDI-Public(01)00801741080128
Combination Product (Y/N)N
Initial Reporter StateSC
Initial Reporter CountryUS
PMA/510(K) Number
K142702
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/04/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number31801
Device Catalogue Number318-01
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/28/2022
Supplement Date Received by Manufacturer04/04/2023
Initial Report FDA Received Date12/21/2022
Supplement Report FDA Received Date04/12/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
Patient Weight12 KG
-
-