• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CONVATEC LTD AQUACEL AG FOAM; DRESSING, WOUND, DRUG

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CONVATEC LTD AQUACEL AG FOAM; DRESSING, WOUND, DRUG Back to Search Results
Model Number 420681
Medical Device Problem Codes Delivered as Unsterile Product (1421); Contamination /Decontamination Problem (2895); Device Contaminated During Manufacture or Shipping (2969)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/01/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported by retailer about identification of visual contamination in the form of brown spots present on every dressing.The product was not used.The photographs and video were received from the complainant.
 
Additional Manufacturer Narrative
Device 17 of 18.Initial reporter name and address: (b)(6).Based on the available information, this event is deemed to be a reportable malfunction.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.(b)(4).
 
Additional Manufacturer Narrative
Additional information - this emdr is being submitted to include the below: h3: device evaluated by mfg? h6: investigation results under imdrf cause investigation code, imdrf investigation.Findings, imdrf cause conclusions.H10: investigation summary.A batch record review was completed, and no discrepancies were found.Aquacel foam ag adh 10x10cm 1x10pk nai was manufactured under system application product (sap) code 1705403 and manufacturing lot number 2c03689 on 28 march 2022.Lot # 2c03689 was sterilized under work order (b)(4) and released on review of results of sterilization provided by sterilization company sterigenics.All the results were within specification and products were released.No nonconformity was identified during the manufacturing process of lot 2c03689.Two photographs and a video were received for this issue and has been evaluated in accordance with work instruction (wis).The photographs confirm the expected lot number, product, and complaint issue, where yellow-brown diffused spots can be seen on the dressing pad at the point of intersection of the silicone border and the release liner fold.The video shows a primary sachet being opened to reveal brown spots on the dressing inside.The samples under complaint were requested for investigation on 01 december 2022 and received on 16th december 2022.A nonconformance was opened for a previous complaint received with an identical failure mode.The nonconformance now covers four (04) complaints against four (04) different batches for the same failure mode.Root cause analysis has identified the brown spots were caused by lubricant transfer from the kiss cut tool during conversion process on delta one (01) manufacturing line.Sample analysis identified this is a mix of lubricant spray and isopropyl alcohol (ipa) cleaner, although it has not been possible to replicate the issue.Several root causes and contributing root causes were identified, and corrective and preventive actions (capa) has been opened to address improvements to prevent recurrence.This issue will be monitored through the post market product monitoring review process, standard operating procedure (sop).To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.Fda registration number.Reporting site: 1049092.Manufacturing site: 1000317571.
 
Event or Problem Description
To date no additional patient or event details have been received.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AQUACEL AG FOAM
Common Device Name
DRESSING, WOUND, DRUG
Manufacturer (Section D)
CONVATEC LTD
first avenue
deeside industrial park
deeside, flintshire CH5 2 NU
UK  CH5 2NU
Manufacturer (Section G)
CONVATEC LTD
first avenue
deeside industrial park
deeside, flintshire CH5 2 NU
UK   CH5 2NU
Manufacturer Contact
pamela meadows
7815 national service road
suite 600
greensboro, NC 
3365424679
MDR Report Key16032142
Report Number1000317571-2022-00383
Device Sequence Number12128280
Product Code FRO
UDI-Device Identifier00768455127153
UDI-Public00768455127153
Combination Product (Y/N)N
PMA/510(K) Number
K123481
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 11/30/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date03/01/2024
Device Model Number420681
Device Lot Number2C03689
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/16/2022
Was the Report Sent to FDA? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/30/2022
Supplement Date Received by Manufacturer02/24/2023
Initial Report FDA Received Date12/22/2022
Supplement Report FDA Received Date03/17/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/28/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-