Model Number EZ-28V
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Corneal Scar (1793); Visual Impairment (2138); Eye Pain (4467)
Date of Event 11/14/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
According to the reporter, device was discarded and is not available for evaluation.As a lot number for the reported device was not provided, a dhr review could not be performed.The trend analysis, risk analysis and/or directions for use review were considered acceptable, with the product performing within anticipated rates.Based on the available information, user related factors (such as loading or handling techniques) and/or procedural factors (such as lens and inserter interaction) may have caused or contributed to this event.
 
Event or Problem Description
Reportedly, after implantation of an intraocular lens (iol) into the left eye it was discovered that iol haptics were bent.The surgeon attempted to straighten the haptics and during the process the iol flipped over and scratched the cornea.On post-op visit it was discovered that lens had shifted causing pain and visual problems for the patient.The lens was explanted 3 days post implant due to lens dislocation and extruded lens in the anterior chamber.A vitrectomy was performed, and the lens was replaced with another iol of the same model and diopter.
 
Event or Problem Description
Additional information was received indicating the patient had a capsule rupture that occurred during cataract emulsification prior to the iol being placed.Therefore the lens was implanted in the sulcus.In the surgeons opinion the likely cause of this event is the kinked haptic in two locations leading to lens instability and subsequent dislocation in the anterior chamber.
 
Additional Manufacturer Narrative
D4: added udi.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EASY-LOAD LENS DELIVERY SYSTEM
Common Device Name
FOLDERS AND INJECTORS, INTRAOCULAR LENS (IOL)
Manufacturer (Section D)
BAUSCH + LOMB
1400 north goodman street
rochester NY 14609
Manufacturer (Section G)
BAUSCH + LOMB
21 north park place blvd.
clearwater FL 33759
Manufacturer Contact
shayan habibi
21 north park place blvd.
clearwater, FL 33759
7277246600
MDR Report Key16042805
Report Number0001313525-2022-00191
Device Sequence Number14676779
Product Code MSS
UDI-Device Identifier00757770520022
UDI-Public(01)00757770520022
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K132481
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer,Health Professional
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 11/28/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberEZ-28V
Device Catalogue NumberEZ-28V
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Supplement Date Received by ManufacturerNot provided
Not provided
Initial Report FDA Received Date12/23/2022
Supplement Report FDA Received Date03/08/2023
03/27/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SILICONE IOL.PROVISC.
Outcome Attributed to Adverse Event Required Intervention;
Patient Age62 YR
Patient SexMale
-
-