Model Number CNA0T0
Medical Device Problem Code Defective Device (2588)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 12/01/2022
Type of Reportable Event Malfunction
Event or Problem Description
An administrator reported that a lens was defective.
 
Additional Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Additional Manufacturer Narrative
Additional information provided in d.9., h.3., h.6., and h.10.The product was returned for analysis and no issues were observed with the device or the lens.The device was returned loose in the carton.The lock-out assembly has been removed.The plunger is oriented correctly.Viscoelastic is observed in the device.The plunger and the lens are advanced into the mid nozzle.The plunger is at the trailing optic edge.The trailing haptic is folded onto the optic.The leading haptic is extended straight.No damage observed to the device or to the lens.The plunger, lens and haptic positions are acceptable.Straight leading haptic observed.The presentation of straight leading haptics is addressed in the product instructions for use (ifu) where it is provided that delivery may proceed with caution and should be managed based on the outlined instructions.Straight leading haptics may occasionally occur, close adherence to the ifu provides the best opportunity for optimal delivery.Possible associated root cause factors may also include: *use of a non-qualified viscoelastic or bss in the delivery system.Material properties of non-qualified ovds may contribute to underfill, overfill, misfolding of the haptics, or other inconsistent folding outcomes.*excessive delay between device preparation and subsequent delivery resulting in the potential for haptic unfolding.*use of the delivery system at operating room temperatures outside of the recommended range of 18 °c (64 °f) to 23 °c (73 °f).Ovd should be allowed to come to operating room temperature over a 30 minute timeframe prior to use.Any of the above listed causes alone, or in combination, may create the reported event.Based on the results from the product history record, the products met release criteria.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLAREON IOL WITH THE AUTONOME DELIVERY SYSTEM
Common Device Name
INTRAOCULAR LENS
Manufacturer (Section D)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI  00000
Manufacturer (Section G)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI   00000
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key16051546
Report Number9612169-2022-00726
Device Sequence Number6394773
Product Code HQL
UDI-Device Identifier00380652393591
UDI-Public00380652393591
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
P190018
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 03/23/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/15/2025
Device Model NumberCNA0T0
Device Lot Number25399045
Was Device Available for Evaluation? Device Returned to Manufacturer
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/02/2022
Supplement Date Received by Manufacturer02/23/2023
Initial Report FDA Received Date12/27/2022
Supplement Report FDA Received Date03/23/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/17/2022
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-