Model Number MA3131
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/29/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the bd maxguard¿ administration set experienced leakage.The following information was provided by the initial reporter: when this sterile iv tubing is connected to a stopcock, it leaks around the threading even if it is threaded/tightly correctly.
 
Additional Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Additional Manufacturer Narrative
H6: investigation summary four photos were received with the customer's complaint regarding the ma3131 infusion set.There is no photo of the leak in action, but the provided information is sufficient to verify that a leak occurred as customer mentioned.Without further information like a physical sample for testing, it is difficult to trace the root cause to a fault in design but rather the new intended design of this set.The male luer end of this set has been modified from a spin collar to a fixed male luer connection and this has been a known confusion with customers who are used to the original configuration.A device history record review for model ma3131 lot number 22069490 was performed.There were no quality notifications issued for the failure mode reported by the customer during the build of this set.
 
Event or Problem Description
It was reported that the bd maxguard¿ administration set experienced leakage.The following information was provided by the initial reporter: when this sterile iv tubing is connected to a stopcock, it leaks around the threading even if it is threaded/tightly correctly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD MAXGUARD¿ ADMINISTRATION SET
Common Device Name
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer (Section G)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key16064812
Report Number9616066-2022-02086
Device Sequence Number17802091
Product Code FPA
UDI-Device Identifier50885403235823
UDI-Public50885403235823
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
PMA/510(K) Number
K083765
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 01/27/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date06/23/2025
Device Model NumberMA3131
Device Catalogue NumberMA3131
Device Lot Number22069490
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/09/2022
Supplement Date Received by Manufacturer01/27/2023
Initial Report FDA Received Date12/28/2022
Supplement Report FDA Received Date02/13/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/21/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1