| Model Number |
123620A |
| Medical Device Problem Code |
Material Protrusion/Extrusion (2979)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
12/12/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
|
| |
|
Event or Problem Description
|
|
It was reported that patient had a foley catheter in place for over 15 years.It was also stated that over the last six months, they have observed that there was blood present during catheter changes about once per month and it was more painful than usual and there was sometimes a bleb at the end of the inflation tubing and the nurse was having difficulty inflating the balloon.Also stated that they have noticed leakage around the foley.Also, when the nurse was inserting the catheter, they insert it just until urine was flowing, then might advance it slightly, but pulls the catheter back before inflating the 30cc balloon.Representative explained that the issue might be related to improper insertion techniques.Advised that on insertion the clinician should ensure that the foley catheter balloon was positioned well within the patient¿s bladder.Then slowly, with a gently, with a gentle, constant force, inflate the foley catheter balloon with the volume prescribed on the package.No medical intervention was reported.
|
| |
|
Event or Problem Description
|
|
It was reported that patient had a foley catheter in place for over 15 years.It was also stated that over the last six months, they have observed that there was blood present during catheter changes about once per month and it was more painful than usual and there was sometimes a bleb at the end of the inflation tubing and the nurse was having difficulty inflating the balloon.Also stated that they have noticed leakage around the foley.Also, when the nurse was inserting the catheter, they insert it just until urine was flowing, then might advance it slightly, but pulls the catheter back before inflating the 30cc balloon.Representative explained that the issue might be related to improper insertion techniques.Advised that on insertion the clinician should ensure that the foley catheter balloon was positioned well within the patient¿s bladder.Then slowly, with a gently, with a gentle, constant force, inflate the foley catheter balloon with the volume prescribed on the package.No medical intervention was reported.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because no sample was returned.It was unknown whether the device had met relevant specifications.It was unknown whether the product had caused the reported failure.A potential root cause for this failure could be poor precaution of the potential failure.A dhr review is not required as the lot number is unknown.The instructions for use were found adequate and states the following: "sterile unless package is opened or damaged.Warning: on catheter, do not use ointments or lubricants having a petrolatum base.They will damage latex and may cause balloon burst.Do not aspirate urine through the drainage funnel wall.Single patient use only.Do not reuse and re-sterilize.For urological use only.Use luer slip syringe.Do not use needle.To deflate catheter balloon: gently insert a syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen.If permitted by hospital protocol, the may be cut off.If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient".H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
|
| |
|