| Model Number |
N/A |
| Medical Device Problem Codes |
Crack (1135); Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
12/12/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported by the customer "we have had four huber needles leak on the hub end." no other information was provided.This report addresses the first device.
|
| |
|
Additional Manufacturer Narrative
|
|
The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) review is not possible, as no manufacturing lot number has been provided by the complainant.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported by the customer "we have had four huber needles leak on the hub end." no other information was provided.This report addresses the first device.Additional information received (b)(6) 2022: the only risk to the patient was that they need to have their port recannulated.
|
| |
|
Event or Problem Description
|
|
It was reported by the customer "we have had four huber needles leak on the hub end." no other information was provided.This report addresses the first device.Additional information received 12/27/2022: the only risk to the patient was that they need to have their port recannulated.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, complaint and lot history review, applicable previous investigation(s), sample (if available), applicable manufacture records, and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a leaking y-site is confirmed and was determined to be supplier related.One 19 ga x 0.75¿ powerloc max with a needleless injection cap attached was returned for evaluation.A functional test involved removing the needleless injection cap and inserting a 12 ml slip-fit syringe at the y-site connection area was performed.Water was injected into the device, and this revealed the crack at the y-site adjacent to the molding seam.A microscopic observation revealed the split to be longitudinally aligned with the molding seam.Whitening around the split was observed with the slip-fit syringe still inserted into the powerloc max y-site.The complaint of the powerloc max device leaking at the y-site is confirmed as this is a known supplier issue.The supplier was notified of this event, and bd is working closely with the supplier to prevent recurrence of the reported event.
|
| |
|