TELEFLEX MEDICAL HOL ML 5MM ENDO APPLIER; APPLIER, SURGICAL, CLIP Back to Search Results
Model Number IPN915189
Device Problem Break (1069)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/06/2022
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
 
Event Description
It was reported that the applier jaws got broken during a test before use.Therefore, a new unit was used instead.
 
Event Description
It was reported that the applier jaws got broken during a test before use.Therefore, a new unit was used instead.
 
Manufacturer Narrative
Qn#(b)(4).The device history for the returned instrument was reviewed and found complete without any irregularities.The instrument was produced at the tecomet, inc.Kenosha, wi facility as part of a 50-pc lot in march of 2022.It was found that this order was made from the correct materials and components and all approved processes were followed.Evaluation of the returned instrument shows that the outer tube assembly is damaged, and the jaws are bent towards the left and the jaws are loose and misaligned, and the jaw rivet pin is pulled through one side of the damaged outer tube assembly.We are able to validate this complaint.After the initial evaluation this instrument was dis-assembled in order to evaluate its internal components and it was found that the inner drive rod is bent, and its bosses are both damaged where they engage the jaws.We suspect that the slightly damaged drive rod bosses caused the jaws to become loose and misaligned in the closed position.We are unable to determine what caused the drive rod to become bent and for it bosses to become damaged and for the jaw pivot pin to be pulled through one side of the damaged outer tube assembly but mishandling of this device at the end user's facility is suspected.All 50 instruments from this lot were 100% visually inspected and function tested prior to shipment to the customer as this is a standardized procedure at this facility for this product line.Due to these findings, no further actions will be taken in response to this complaint and this record will be deemed closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HOL ML 5MM ENDO APPLIER
Type of Device
APPLIER, SURGICAL, CLIP
Manufacturer (Section D)
TELEFLEX MEDICAL
morrisville NC
Manufacturer (Section G)
TELEFLEX MEDICAL
3015 carrington mill blvd
morrisville NC 27560
Manufacturer Contact
effie jefferson
3015 carrington mill blvd
morrisville 27560
9194332672
MDR Report Key16077887
MDR Text Key308354749
Report Number3011137372-2022-00255
Device Sequence Number1
Product Code GDO
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 12/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/30/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberIPN915189
Device Catalogue Number544965
Device Lot Number06A2244658
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/06/2023
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage A
Patient Sequence Number1
Treatment
NONE REPORTED; NONE REPORTED
-
-