• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BIOMET UK LTD. CER OPTION TYPE 1 TPR SLEVE +6; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/CERAMIC/POLYMER, CEMENTED OR NON-POROUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BIOMET UK LTD. CER OPTION TYPE 1 TPR SLEVE +6; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/CERAMIC/POLYMER, CEMENTED OR NON-POROUS Back to Search Results
Model Number N/A
Medical Device Problem Code Component or Accessory Incompatibility (2897)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/13/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was found that taper sleeve did not match with ceramic head during hip surgery.It was reported that this was due to the +6mm trial head, and the +6mm sleeves not recreating the same construct.No consequences or impact to the patient.Due diligence is in progress for this complaint; to date no additional information or product has been received.
 
Additional Manufacturer Narrative
(b)(4).Report source: foreign: australia.Concomitant medical products: cer option type 1 tpr sleve +6 item# 650-1068, lot#3066236.Cer opt type 1 tpr sleve 0mm item# 650-1066, lot#2020020470.+6mm mod hd endo ii trial item# 31-401161, lot# unknown.Multiple mdr reports were filed for this event, please see associated reports: 3002806535-2023-00010 & 3002806535-2023-00011.Investigation of this incident is currently ongoing.Once the investigation is completed, a supplemental 3500a will be submitted.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
Cmp-(b)(4).This follow-up report is being submitted to relay additional information.Review of the photographs provided by the hospital identified that an endo trial is being used during the g7 surgery.There are specific g7 trials available for trialling and the use of the endo trials is considered as being off label.Nothing further can be gained from review of the photographs.Review of the device history records identified no deviations or anomalies during manufacturing.Devices are used for treatment.The reported products were reviewed for compatibility and it was determined that the endo trial is not compatible for trialling a g7 dual mobility construct.Medical records were not provided.The root cause of the reported issue is attributed to use error - non indicated use of product.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
(b)(4).This follow-up report is being submitted to relay corrected information.The following sections were updated: b4, b5, d9, d10, g3, g6, h1, h2, h3, h10.D-10 cer option type 1 tpr sleve +6 item#650-1068 lot#3066236.Cer opt type 1 tpr sleve 0mm item#650-1066 lot#2020020470.+6mm mod hd endo ii trial item#31-401161 lot#unknown.Act artic e1 hip brg 28x40mm item#ep-200146 lot#65690351.Cer bioloxd option hd 28mm item#650-1055 lot#3087400.Cer option type 1 tpr sleve +3 item#650-1067 lot#276250.Tloc 133 mp sp tp1 bm so 6.0 item#51-118060 lot#3954835.G7 osseoti 3 hole shell 50mm d item#110010243 lot#r7224675a.G7 dual mobility liner 40mm d item#110024462 lot#506770 the device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.
 
Event or Problem Description
Upon reassessment of the reported event, it was determined a medwatch report should not have been filed because item and lot number of returned products etching is not that of the reported products within the complaint.Furthermore, the item numbers etched onto the parts are not recognized as zimmer biomet product numbers.Given this information, this medwatch will be voided.
 
Additional Manufacturer Narrative
(b)(4).Upon reassessment of the reported event, it was determined a medwatch report should not have been filed because item and lot number of returned products etching is not that of the reported products within the complaint.Furthermore, the item numbers etched onto the parts are not recognized as zimmer biomet product numbers.Given this information, this medwatch will be voided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CER OPTION TYPE 1 TPR SLEVE +6
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/CERAMIC/POLYMER, CEMENTED OR NON-POROUS
Manufacturer (Section D)
BIOMET UK LTD.
waterton industrial estates
bridgend CF31 3XA
UK  CF31 3XA
Manufacturer (Section G)
BIOMET UK LTD.
waterton industrial estates
bridgend CF31 3XA
UK   CF31 3XA
Manufacturer Contact
christina arnt
56 e. bell dr.
warsaw, IN 46582
5745273773
MDR Report Key16120215
Report Number3002806535-2023-00009
Device Sequence Number12900973
Product Code LZO
UDI-Device Identifier00880304521902
UDI-Public(01)00880304521902(17)270831(10)2911080
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K200959
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 05/30/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number650-1068
Device Lot Number2911080
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/13/2022
Supplement Date Received by Manufacturer02/09/2023
03/16/2023
05/18/2023
Initial Report FDA Received Date01/09/2023
Supplement Report FDA Received Date03/06/2023
03/31/2023
05/30/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/31/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexPrefer Not To Disclose
-
-