ZIMMER ORTHOPAEDIC MFG. LTD. ARTICULAR SURFACE (MC) LEFT 12 MM HEIGHT; PROSTHESIS, KNEE Back to Search Results
Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Thrombosis/Thrombus (4440)
Date of Event 11/29/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Multiple mdr reports were filed for this event, please see associated report: 0001822565-2023-00140, 0001822565-2023-00141.Medical product: femur trabecular metal (cr) standard porous, item# 42502806801, lot# 65434907.Natural tibia trabecular metal two-peg porous fixed bearing left size g, item# 42530007901, lot# 77012032.Customer has indicated that the product will not be returned to zimmer biomet for investigation as it remains implanted.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that a patient developed a deep vein thrombus (dvt) requiring medical intervention ten days post implantation.All components remain implanted.Attempts to obtain additional information have been made; however, no more information is available.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Procedural related complications are influenced by the type of surgery, patients pre-existing comorbidities, and perioperative management.Deep vein thrombosis (blood clot), or dvt, occurs when a blood clot forms in one of the deep veins of the body.This can happen if a vein becomes damaged or if the blood flow within a vein slows down or stops.Total joint patients are typically placed on medication post-operatively to prevent dvt formation.Even with the administration of preventive medication, dvts can still develop.As the complaint indicated, a post-operative complication occurred, and medical intervention was required for treatment.The patient was also obese and a smoker which both increase risk for dvt.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARTICULAR SURFACE (MC) LEFT 12 MM HEIGHT
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER ORTHOPAEDIC MFG. LTD.
building no 2 east park
shannon industrial estate
shannon, county clare
EI 
Manufacturer (Section G)
ZIMMER ORTHOPAEDIC MFG. LTD.
building no 2 east park
shannon industrial estate
shannon, county clare
EI  
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key16187080
Report Number3007963827-2023-00007
Device Sequence Number14029417
Product Code MBH
UDI-Device Identifier00889024469396
UDI-Public(01)00889024469396(17)270615(10)65392084
Combination Product (Y/N)N
Initial Reporter StateOR
Initial Reporter CountryUS
PMA/510(K) Number
K150090
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Study,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/01/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number42512100912
Device Lot Number65392084
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/29/2022
Supplement Date Received by Manufacturer01/26/2023
Initial Report FDA Received Date01/17/2023
Supplement Report FDA Received Date02/02/2023
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured07/04/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
Patient Weight115 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-