Investigation is in progress, once completed a supplemental will be submitted.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster inc., or its employees that the report constitutes an admission that the product, biosense webster inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# (b)(4).
|
|
It was reported that a female patient underwent a premature ventricular contraction (pvc) atrial fibrillation (afib) ablation procedure with a soundstar® eco diagnostic ultrasound catheter and the patient suffered a cardiac tamponade requiring pericardiocentesis.It was reported that during a pvc ablation case, pericardial effusion was noticed.The caller reported there were no visible signs on the patient.The pericardial effusion was confirmed by intracardiac echocardiography (ice).The caller reported that the medical intervention provided was a pericardiocentesis and 150ml of fluid was removed.Additional information was received indicating this adverse event was discovered during use of biosense webster products, during the mapping phase.No ablation was performed, as such, there was no steam pop.The physicians opinion is that he perforated with ice catheter.There was no malfunction of equipment.The patient's outcome from the adverse event is that it was improved.It is uncertain if the patient required extended hospitalization because of the adverse event, the patient was transferred to intensive care unit (icu) for observation.A smartablate generator was used during this case with the correct catheter settings selected.The flow setting for the pump were set per instructions for use (ifu), however, ablation has not been started.At a transseptal puncture was performed with a brk needle.No error messages were noted.Dashboard, vector, and visitag force visualization features were used.Parameters for stability used with visitiag were range 2.5, time 3sec, force over time (fot) 25%, however, ablation had not started.No additional filter was used with the visitag.Fti was the color option but no was ablation performed.Ablation catheter was inside body, but no ablation had been performed, only the soundstar® eco diagnostic ultrasound catheter has been used.The event will be reported against the.The cardiac tamponade will be reported against the soundstar® eco diagnostic ultrasound catheter due to the "physicians opinion is that he perforated with ice, and no malfunction of equipment.".
|