STRYKER INSTRUMENTS-KALAMAZOO UNIVERSAL WIRE/PIN COLLET; INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT Back to Search Results
Model Number 4500-125-000
Medical Device Problem Code Material Disintegration (1177)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/31/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Reported events: 5 events were reported for this quarter.Product return status: 4 devices were received.1 device investigation type has not yet been determined.Additional information: 5 devices were not labeled for single-use.5 devices were not reprocessed or reused.
 
Event or Problem Description
This report summarizes 5 malfunction events in which the device was shedding metal debris.3 events had no patient involvement; no patient impact.2 events had patient involvement; no patient impact.
 
Event or Problem Description
This report summarizes 5 malfunction events in which the device was shedding metal debris.4 events had no patient involvement; no patient impact.1 event had patient involvement; no patient impact.
 
Additional Manufacturer Narrative
This record is a consolidation of records summarized as a part of the fda voluntary malfunction summary reporting program.Supplemental rationale: 5 previously reported events are included in this follow-up record.Product return status: 5 devices were received.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNIVERSAL WIRE/PIN COLLET
Common Device Name
INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT
Manufacturer (Section D)
STRYKER INSTRUMENTS-KALAMAZOO
4100 east milham avenue
kalamazoo MI 49001
Manufacturer (Section G)
STRYKER INSTRUMENTS-KALAMAZOO
4100 east milham avenue
kalamazoo MI 49001
Manufacturer Contact
colette chung
1941 stryker way
portage, MI 49002
2693237700
MDR Report Key16261994
Report Number3015967359-2023-00271
Device Sequence Number4386046
Product Code HWE
UDI-Device Identifier07613327467468
UDI-Public07613327467468
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Number of Events Summarized5
Summary Report (Y/N)Y
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/25/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number4500-125-000
Device Catalogue Number4500125000
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 12/31/2022
Supplement Date Received by Manufacturer12/31/2022
Initial Report FDA Received Date01/29/2023
Supplement Report FDA Received Date04/25/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-