TELEFLEX MEDICAL SDN. BHD. SAFETY CLR MURPHY CUF ET; TUBE, TRACHEAL (W/WO CONNECTOR Back to Search Results
Model Number IPN041504
Medical Device Problem Code Disconnection (1171)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 01/10/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Other remarks: n/a.Corrected data: n/a.
 
Event or Problem Description
It is reported that "on multiple occasions, while in the middle of a surgical case, the detachable plastic piece on the top of the endotracheal tube has come off completely with the circuit attached while the patient is intubated.Last week this happened twice in the middle of our first case." after further correspondence with the reporter, the customer does not have any further information regarding the specifics of the events.If additional information is received, the complaint file will be updated.See associated mdrs 8040412-2023-00046, 8040412-2023-00047, 8040412-2023-00025, 8040412-2023-00048.
 
Additional Manufacturer Narrative
Qn#(b)(4).Complaint verification testing could not be performed as it was reported that the sample is not available for return.A device history record review was performed and no relevant findings were identified.Without the device to evaluate the complaint could not be confirmed and the probable cause could not be determined from the available information.Teleflex will continue to monitor and trend for reports of this nature.
 
Event or Problem Description
It is reported that "on multiple occasions, while in the middle of a surgical case, the detachable plastic piece on the top of the endotracheal tube has come off completely with the circuit attached while the patient is intubated.Last week this happened twice in the middle of our first case." after further correspondence with the reporter, the customer does not have any further information regarding the specifics of the events.If additional information is received, the complaint file will be updated.Associated mdrs 8040412-2023-00046, 8040412-2023-00047, 8040412-2023-00025, 8040412-2023-00048.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SAFETY CLR MURPHY CUF ET
Common Device Name
TUBE, TRACHEAL (W/WO CONNECTOR
Manufacturer (Section D)
TELEFLEX MEDICAL SDN. BHD.
perak, west malaysia
Manufacturer (Section G)
TELEFLEX MEDICAL SDN. BHD.
lot no : pt2577 jalen perusahaan
4 kamunting industrial estate
perak, west malaysia 34600
MY   34600
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key16272613
Report Number8040412-2023-00049
Device Sequence Number18015399
Product Code BTR
UDI-Device Identifier14026704341440
UDI-Public14026704341440
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K961837
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/18/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/28/2026
Device Model NumberIPN041504
Device Catalogue Number112082080
Device Lot NumberKME21J1295
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/18/2023
Supplement Date Received by Manufacturer03/09/2023
Initial Report FDA Received Date01/31/2023
Supplement Report FDA Received Date03/09/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured09/28/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-