Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Hematoma (1884); Pain (1994)
|
Event Type
Injury
|
Manufacturer Narrative
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.This report is for an unknown screws: 6.5 mm cannulated /unknown lot.Part and lot numbers are unknown; udi number is unknown.Complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Event Description
|
Device report from synthes reports an event in france as follows: this report is being filed after the review of the following journal article: cornelis, f.H.Et al (2022), percutaneous screw fixation of pelvic bone metastases using cone-beam computed tomography navigation, diagnostic and interventional imaging, vol.103 (xx), pages 367-374 (france).The purpose of this retrospective study was to evaluate the efficacy of cbct navigation to achieve percutaneous screw fixation of pelvic bone metastases.Between january 2019 to january 2021, a total of 35 patients (12 male and 23 female) with a mean age of 62 ± 11.3 [sd] years (range: 39-89 years) who underwent percutaneous screw fixation of the pelvic bone performed under cbct guidance were included.A stainless-steel 6.5-mm cannulated screw (depuysynthes, johnson & johnson) was inserted on the guidewire and locked on the cortical bone and a polymethyl-methylacrylate from a competitor was finally injected through the screw to provide additional consolidated effect at the tip of the screw while the screw heads remained in the cortical bone.The median follow-up period was 6 months; iqr: 6-6.5 months.The following complications were reported as follows: 13 patients died during follow-up related to cancer progression, but only 3 at less than six months.18 patients reported minor adverse events (pain, hematoma).This report involves one unk - screws: 6.5 mm cannulated.This is report 1 of 1 for (b)(4).
|
|
Search Alerts/Recalls
|
|
|