Olympus reviewed the following literature titled, "a novel self-assembling peptide hemostatic gel as an option for initial hemostasis in endoscopic sphincterotomy-related hemorrhage: a case series".Endoscopic sphincterotomy (est) is a fundamental procedure of therapeutic endoscopic retrograde cholangiopancreatography, with post-est bleeding as a serious adverse event.Although there are various hemostatic methods for post-est bleeding, there is no consensus regarding the treatment choice.Purastat is a novel self-assembling peptide developed as a hemostatic agent.We report six cases of est-related hemorrhage with initial hemostasis achieved using purastat.The cases were observed in four men and two women, with an average age of 77.8 years.Est was performed for biliary drainage in four cases and for stone removal in two cases.Bleeding occurred during the same session as est in fve of six cases, with the remaining case showing bleeding 4 days after est.As all patients with est-related hemorrhage presented oozing with stable vital signs, we selected purastat as frst-line hemostasis in each case.We applied purastat using a dedicated catheter with the tip pressed against the bleeding point.Hemostasis was confirmed without additional procedure in all cases.No adverse events were noted after the procedures.As purastat hemostasis is effective, feasible, and safe for est-related hemorrhage, purastat may be an option for initial hemostasis, although it is limited to oozing.Type of adverse events/number of patients: hyperamylasemia (non-serious) - 1 patient.Est-related hemorrhage - 6 patients.This literature article requires 18 reports.The related patient identifiers are as follows: 1.(b)(6):kd-vc411q-0720(patient1: 66 years old, male, bleeding).2.(b)(6):tjf-260v(patient1: 66 years old, male, bleeding).3.(b)(6):tjf-q290v(patient1: 66 years old, male, bleeding).4.(b)(6):kd-vc411q-0720(patient2: 77 years old, female, bleeding).5.(b)(6):tjf-260v(patient2: 77 years old, female, bleeding).6.(b)(6):tjf-q290v(patient2: 77 years old, female, bleeding).7.(b)(6):kd-vc411q-0720(patient3: 86 years old, male, bleeding & hyper-amylasemia).8.(b)(6):tjf-260v(patient3: 86 years old, male, bleeding & hyper-amylasemia).9.(b)(6):tjf-q290v(patient3: 86 years old, male, bleeding & hyper-amylasemia).10.(b)(6):kd-vc411q-0720(patient4: 72 years old, male, bleeding).11.(b)(6):tjf-260v(patient4: 72 years old, male, bleeding).12.(b)(6):tjf-q290v(patient4: 72 years old, male, bleeding).13.(b)(6):kd-vc411q-0720(patient5: 88 years old, female, bleeding).14.(b)(6):tjf-260v(patient5: 88 years old, female, bleeding).15.(b)(6):tjf-q290v(patient5: 88 years old, female, bleeding).16.(b)(6):kd-vc411q-0720(patient6: 78 years old, male, bleeding).17.(b)(6):tjf-260v(patient6: 78 years old, male, bleeding).18.(b)(6):tjf-q290v(patient6: 78 years old, male, bleeding).This medwatch report is for patient identifier (b)(6).There is no report of any olympus device malfunction in any procedure described in this study.
|