| Model Number |
TG0654509 |
| Medical Device Problem Code |
Mechanical Problem (1384)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/09/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Conclusion not yet available, evaluation in process.A follow-up will be submitted as soon as the investigation is complete.Oscor inc.Is submitting the above report to comply with 21 cfr part 803, the medical device reporting regulation.The report is based upon information obtained by oscor inc.Which the company may not have been able to investigate or verify prior to the date the report was required by fda.This report does not constitute an admission that the device, oscor inc., or its employees, caused or contributed to the event described in this report.Nor does this report reflect a conclusion by fda, oscor inc., or its employees, that the report constitutes an admission that the device, oscor inc., or its employees caused or contributed to the event described in this report.
|
| |
|
Event or Problem Description
|
|
This device was used in an iliac recanalization procedure, event occurred at the time of the puncture.The device was inserted into the patient, while the representative was holding the dilator tight with her fingers.She reported excessive force was used.Per the end user the dilator does not attached to the guide and this causes the device to malfunction.The procedure was delayed less than 30 minutes, but was successfully completed using the same device.It was reported there was no harm to the patient.
|
| |
|
Event or Problem Description
|
|
Additional information reported.The tourguide was used in lliac recanalization procedure.The event occurred at the time of the puncture, there was a delay of less than 30 minutes and excessive force was used.The procedure was successfully completed using the same device.There was no patient harm.
|
| |
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis; therefore, the investigation was focused on product documentation.The device history records were reviewed to confirm that the device passed all applicable in-process and final inspections.However, the following controls are in place to mitigate the reported product issue.Capa was opened to investigate the root cause and implement corrective action to prevent recurrence of this issue.Per procedure (thermoplastic overmolding of parts).Sample size: 100%.While parts are in process: perform a visual inspection to verify the parts meet applicable cosmetic criteria (e.G, flash, short shots, gate blush, fm, etc.).Per qa procedure (destino dilator in-process and final inspection).Sample size: 5 first and 5 last good shots inspect 100%.Visual inspection: hub to be round and smooth, no irregularities inside.At 12-18" distance, hub shape should be as per drawing, flash <0.75 mm or pinch should not exceed 0.2 mm (use profile projector if needed).Measure id of dilator hub by inserting appropriate pin gauge through hub.The instructions for use (ifu) informs the user: place dilator inside the sheath and snap on both hubs together.Thread the dilator/sheath assembly over the guidewire, using a slight twisting motion.Note: any device/component inserted through the hemostatic valve of the sheath should be wet and placed through the center of the valve to prevent tearing of the seal and leakage.Corrective actions initiated to investigate and mitigate the reoccurrence of this issue.Oscor inc.Is submitting the above report to comply with 21 cfr part 803, the medical device reporting regulation.The report is based upon information obtained by oscor inc.Which the company may not have been able to investigate or verify prior to the date the report was required by fda.This report does not constitute an admission that the device, oscor inc., or its employees, caused or contributed to the event described in this report.Nor does this report reflect a conclusion by fda, oscor inc., or its employees, that the report constitutes an admission that the device, oscor inc., or its employees caused or contributed to the event described in this report.
|
| |
|