AOMORI OLYMPUS CO., LTD. SINGLE USE ELECTROSURGICAL KNIFE KD-655 Back to Search Results
Model Number KD-655Q
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Hemorrhage/Blood Loss/Bleeding (1888); Perforation (2001)
Date of Event 08/23/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Since the literature described "dual-knife", we selected "kd-655q" as a representative product.The product was unknown but a representative product was chosen for processing purposes.The suspect device has not been returned to olympus for evaluation.The investigation is in process.The literature article is attached for additional information.Once the investigation has been completed, a supplemental report will be submitted with device evaluation results.
 
Event or Problem Description
Olympus reviewed the following literature titled, "modified cap-assisted endoscopic mucosal resection versus endoscopic submucosal dissection for the treatment of rectal neuroendocrine tumors #10 mm: a randomized noninferiority tria." introduction: although recent guidelines recommend endoscopic resection of rectal neuroendocrine tumors (net) =10 mm, there is no consensus on which endoscopic modality should be performed.We aimed to compare the safety and efficacy of modified cap-assisted endoscopic mucosal resection (memr-c) and endoscopic submucosal dissection (esd) methods for the treatment of rectal net =10 mm.Methods: a randomized noninferiority trial comparing memr-c and esd was conducted.The primary outcome was the histological complete resection rate; the secondary outcomes included en bloc resection rate, operation time, complications, and so on.Subgroup analyses and follow-up were also performed.Results: ninety patients were enrolled, and 79 patients with pathologically confirmed rectal net were finally analyzed, including 38 cases of memr-c and 41 cases of esd.Histological complete resection rate was 97.4% in the memr-c group and 92.7% in the esd group.The noninferiority of memr-c compared with that of esd was confirmed because the absolute difference was 4.7% (2-sided 90% confidence interval, -3.3% to 12.2%; p = 0.616).En bloc resection and successful removal of rectal net were achieved in all patients.Advantages of memr-c over esd included shorter operation time (8.89 ± 4.58 vs 24.8 ± 9.14 minutes, p < 0.05) and lower hospitalization cost ((b)(6), p < 0.05).Postoperative complications were recorded in 4 patients who received memr-c and 2 patients in the esd group (11.5% vs 4.9%, p = 0.509), which were all well managed using endoscopy.Similar findings were observed when subgroup analysis was performed.Type of adverse events/number of patient: bleeding (n = 5), perofration (n = 1).This literature article requires 2 reports.The related patient identifiers are as follows: (b)(6) for mh-593 and (b)(6) for kd-655q.This medwatch report is for patient identifier (b)(6).There is no report of any olympus device malfunction in any procedure described in this study.
 
Additional Manufacturer Narrative
This supplemental report is being submitted to provide a correction to h6 code (type of investigation).Code 4112 added that was inadvertently not included on the previous submission.
 
Event or Problem Description
The following additional information was received: the was no malfunction, nor adverse event that occurred during use of an olympus device in any of the procedures described in the article.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the serial and/or lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the relationship between the device and the adverse event cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Therefore, the root cause cannot be determined.This supplemental report includes additional information added to b5.Also, a correction has been made to g2 to include information that was inadvertently not included on the initial medwatch.Olympus will continue to monitor field performance for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE ELECTROSURGICAL KNIFE KD-655
Common Device Name
SINGLE USE ELECTROSURGICAL KNIFE
Manufacturer (Section D)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori 036-0 357
JA  036-0357
Manufacturer (Section G)
AOMORI OLYMPUS CO., LTD.
2-248-1 okkonoki
kuroishi-shi, aomori
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key16401674
Report Number9614641-2023-00248
Device Sequence Number17569289
Product Code KNS
UDI-Device Identifier04953170405631
UDI-Public04953170405631
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K171158
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Study,Literature,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 03/14/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberKD-655Q
Device Lot NumberUNKNOWN(LITERATURE)
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/19/2023
Supplement Date Received by Manufacturer03/14/2023
03/14/2023
Initial Report FDA Received Date02/20/2023
Supplement Report FDA Received Date03/14/2023
03/14/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NON-OLYMPUS DEVICE: T-TYPE ESD KNIFE
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient SexUnknown
-
-