| Model Number |
0119L16 |
| Medical Device Problem Code |
Inadequate or Insufficient Training (1643)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/01/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that the survey respondent stated no, they did not agree that the instructions for use (ifu) for the following bard or becton dickinson products provides sufficient information about the products and their medical applications because of unclear information, missing information, lack of maintenance documentation or guidelines, inadequate instructions for healthcare professional and inadequate or insufficient training in relation to lubricath®, 3-way, 5cc balloon, french size 16.
|
| |
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
|
| |
|
Event or Problem Description
|
|
It was reported that the survey respondent stated no, they did not agree that the instructions for use (ifu) for the following bard or becton dickinson products provides sufficient information about the products and their medical applications because of unclear information, missing information, lack of maintenance documentation or guidelines, inadequate instructions for healthcare professional and inadequate or insufficient training in relation to lubricath®, 3-way, 5cc balloon, french size 16.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because no sample was returned.A potential root cause for this failure could be due to "vendor/printer error".The lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: "to deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.If permitted by hospital protocol, the valve arm may be severed.If this fails, contact adequately trained professional for assistance, as directed by hospital protocol." h11: section a through f - the information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.H3 other text : the device was not returned.
|
| |
|