| Model Number |
0119L20 |
| Medical Device Problem Code |
Missing Information (4053)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/01/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.Device evaluated by mfr: the device was not returned.
|
| |
|
Event or Problem Description
|
|
It was reported that the survey respondent stated no, they did not agree that the instructions for use (ifu) for the following bard or becton dickinson products provides sufficient information about the products and their medical applications because of unclear information, missing information, lack of maintenance documentation or guidelines, inadequate instructions for healthcare professional and inadequate or insufficient training in relation to lubricath®, 3-way, 5cc balloon, french size 20.
|
| |
|
Event or Problem Description
|
|
It was reported that the survey respondent stated no, they did not agree that the instructions for use (ifu) for the following bard or becton dickinson products provides sufficient information about the products and their medical applications because of unclear information, missing information, lack of maintenance documentation or guidelines, inadequate instructions for healthcare professional and inadequate or insufficient training in relation to lubricath®, 3-way, 5cc balloon, french size 20.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive.No sample was returned for evaluation.A potential root cause for this failure could be "incorrect/ missing translation; missing instructions".The lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: "caution: this product contains natural rubber latex which may cause allergic reactions.Sterile unless package is opened or damaged.Warning: on catheter, do not use ointments or lubricants having petrolatum base.They will damage latex and may cause the balloon to burst.Caution: do not aspirate urine through drainage funnel wall.Storage: store catheters at room temperature away from direct exposure to light, preferably in the original box.Single patient use only.Do not reuse.Do not resterilize.For urological use only.Valve type: use luer slip tip syringe.Do not use needle.Recommended inflation capacities 3cc balloon: use 5ml sterile water 5cc balloon: use 10ml sterile water 15cc balloon: use 20ml sterile water 20cc balloon: use 25ml sterile water 30cc balloon: use 35ml sterile water 40cc balloon: use 45ml sterile water 75cc balloon: use 80ml sterile water do not exceed recommended capacities." h11: section a through f - the information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.H3 other text : the device was not returned.
|
| |
|
Search Alerts/Recalls
|