| Model Number |
413418 |
| Medical Device Problem Code |
Malposition of Device (2616)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(6).Complainant country: canada.Based on the available information, this event is deemed to be a reportable malfunction.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.Fda registration number: (b)(4).
|
| |
|
Event or Problem Description
|
|
The end user reported that one of samples of the wafer had starter hole off centered.The end user also stated that wafer was mostly looked off centered starter hole, as there was much more material to roll back on one side than the other.The flange ring itself was in the middle of the appliance.The product was not used.A photograph depicting the issue was received from the complainant.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information - this emdr is being submitted to include the below: h6: investigation results under imdrf cause investigation code, imdrf investigation findings, imdrf cause conclusions.C22 and d17 were selected under imdrf investigation findings and imdrf cause conclusions respectively because they are not adequately described by any other term for "an over the time fade on the criteria for the decentralization defects and the correct use of the tooling available on the line".Batch record review: lot 2l02923 was manufactured on 29/nov/2022, in ats #2 line, with a total of (b)(4) market units (mkus).Compliance engineer performed a batch record review on 29/mar/2023, to verify if all the applicable procedures were followed and no issues were found; all the components for assembly were correct per bill of materials (bom) and all the tooling information documented was also correct, system application product (sap) material id 1703890 and manufacturing order (b)(4).The batch record review supports that there were no discrepancies related to the issue reported.Photograph, video and/or physical sample evaluation: photo related to the reported problem is available for evaluation.Conclusion summary of the related event: during the event summary and impact evaluation of this nonconformance report (ncr), with the support of the triage team expertise, the most probable causes of the problem identified: after performing the root cause analysis, it was concluded that the non-conformance is related to an over the time fade on the criteria for the decentralization defects and the correct use of the tooling available on the line.The appropriate actions will be taken through the corrective and preventive actions (capas).The investigation associated with related event record has been approved and was complete.No additional action is required, and this complaint will be closed.This issue will be monitored through the post market product monitoring review process.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.Fda registration number: reporting site: 1049092.Manufacturing site: 9618003.
|
| |
|
Event or Problem Description
|
|
To date no additional patient or event details have been received.
|
| |
|