(b)(4).Product background: the opt980 optiflow + mask interface adapter is a patient interface used for delivery of humidified respiratory gases and allows for the connection of a heated breathing tube to a standard vented face mask or to a patient's tracheostomy.Optiflow + interfaces are designed for use with the airvo 2 series of humidification devices and is also compatible with the fisher and paykel (f&p) mr850 and 950 humidification system devices.The airvo 2 device is intended for use with spontaneously breathing patients who would benefit from receiving high flow warmed and humidified respiratory gases.The airvo 2 should not be used for life support purposes, and appropriate patient monitoring must be used at all times.The interface includes a lanyard which is placed around the patient's neck or attached to the patient's clothing or bedding to remove the load of the breathing circuit from the patient's interface.Method: the complaint opt980 optiflow + mask interface adapter was received at fisher & paykel healthcare (f&p) in new zealand for investigation, where it was visually inspected.Our investigation is based on our evaluation of the subject device, information provided by the customer, previous investigations of similar complaints, and our knowledge of the product.Results: the returned opt980 optiflow + mask interface adapter had the lanyard removed.Visual inspection of the opt980 optiflow + mask interface adapter revealed that the tubing was torn near the manifold, and that the tubing had been stretched.Conclusion: our investigation was unable to determine the cause of the observed damage to the opt980 optiflow + mask interface adapter.Based on our knowledge of the product the tubing was likely subjected to excessive force.F&p's manufacturing controls for the optiflow + tubing include inspections during production for visual defects including cracks, tears, moulding defects, contamination, inclusions, discoloration and stretching or deformation.The subject opt980 optiflow + mask interface adapter would have met the required specifications.The user instructions which accompany the opt980 optiflow + mask interface adapter show in pictorial format the correct placement and fitting of the interface, including ensuring the lanyard and the tubing clip are appropriately attached.The user instructions also state: "attach breathing tube clip to a secure location (e.G., clothing or bedding) to support the interface." "appropriate patient monitoring must be used at all times.Failure to monitor the patient may result in loss of therapy, serious injury or death." "do not crush or stretch tube, to prevent loss of therapy." "failure to use the set-up described above can compromise performance and affect patient safety.".
|