|
It was reported, after a universa firm ureteral stent set was placed during an unknown procedure for an unspecified amount of time, the tether separated from the stent when the patient attempted removal of the stent from home.The patient returned to the hospital to have the stent removed.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Additional information has been requested but is not available at this time.
|
|
Blank fields on this form indicate the information is unknown or unavailable.Summary of event: it was reported, after a universa firm ureteral stent set was placed during an unknown procedure for an unspecified amount of time, the tether separated from the stent when the patient attempted removal of the stent from home.The patient returned to the hospital to have the stent removed.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Additional information was received 22mar2023: the stent was in place a " few weeks." the stent was not encrusted.Investigation evaluation: reviews of the complaint history, device history record (dhr), instructions for use (ifu), and quality control (qc) procedures were conducted during the investigation.Interviews of personnel were also conducted during the investigation.The complaint device was not returned; therefore, no functional testing or visual inspections could be performed.A search of the device history record found no related non-conformances reported for lot 14959538.A complaint history database search showed no other related complaints associated with the complaint device lot.Because there are no related non-conformances, adequate inspection activities have been established, there is objective evidence that the dhr was fully executed, and no other lot related complaints that have been received from the field, it was concluded that there is no evidence that nonconforming product exists in house or in field.Cook also reviewed product labeling.Ifu t_uss_rev5 (¿universa firm ureteral stents and stent sets¿), supplied with the device, states the following in consideration of the reported failure mode: ¿precautions: the tether should be removed if the stent is to remain indwelling longer than 14 days.¿ the information provided upon review of complaint file, device history record, complaint history, and quality control documents provides evidence to support that the device was manufactured to specification.The complaint reported by the customer of the stent¿s tether becoming separated from the stent was confirmed via customer testimony.Based upon the available information and results of the investigation, cook has concluded that the exact cause for the separation could not be established.However, based on the details received by the customer about the stent being in place for a "few weeks", it appears that the precaution of ¿the tether should be removed if the stent is to remain indwelling longer than 14 days¿ that is stated in the ifu, may not have been heeded.The appropriate personnel have been notified and cook will continue to monitor for similar events.Per the quality engineering risk assessment, no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|