| Model Number |
690-00-28F |
| Medical Device Problem Codes |
Detachment of Device or Device Component (2907); Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Code |
Joint Dislocation (2374)
|
| Date of Event |
02/22/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.Device not returned to the manufacturer.
|
| |
|
Event or Problem Description
|
|
The following was reported: patient had second hip revision procedure in two months.Her third hip revision procedure in total.On this latest occasion, her hip prosthesis had dislocated similar to the previous event.Specifically, she had a trident constrained insert in-situ and the bipolar head had dislocated from the insert that it had been pre-assembled in.The insert was still in the acetabular shell but the bipolar head was completely disengaged from it.The bipolar head still had the femoral head within it which itself was still intact on the cone body implant trunnion.
|
| |
|
Event or Problem Description
|
|
The following was reported: patient had second hip revision procedure in two months.Her third hip revision procedure in total.On this latest occasion, her hip prosthesis had dislocated similar to the previous event.Specifically, she had a trident constrained insert in-situ and the bipolar head had dislocated from the insert that it had been pre-assembled in.The insert was still in the acetabular shell but the bipolar head was completely disengaged from it.The bipolar head still had the femoral head within it which itself was still intact on the cone body implant trunnion.Update: as per intake form, the surgeon explanted the trident constrained liner, ceramic head, trident cluster shell, screws and the cone body.
|
| |
|
Additional Manufacturer Narrative
|
|
Reported event: an event regarding disassociation involving a trident liner ¿was reported.¿¿the event was confirmed as the bipolar head containing the ceramic head was returned independent to the constrained liner.Method & results: -device evaluation and results: visual inspection of the returned device indicated damage consistent with explantation.The ring disassociated from the insert along with a screw still assembled.-clinician review: no medical records were received for review with a clinical consultant.-device history review: review of the product history records indicate devices were manufactured and accepted into final stock with no reported relevant discrepancies.-complaint history review: there has been no other event for the lot referenced.Conclusion: the event was confirmed as the bipolar head containing the ceramic head was returned independent to the constrained liner.Further information such as pre- and post-operative x-rays, operative reports as well as patient history and follow-up notes are needed to complete the investigation for determining root cause.No further investigation for this event is possible at this time.If additional information become available to indicate further evaluation is warranted, this record will be reopened.
|
| |
|