| Model Number |
VTICM5_12.6 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Fatigue (1849); Headache (1880); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
02/28/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Health effect clinical code: 4581 hyperopic/showing cyl.Type of investigation: 4110 lens work order search: no similar complaint type events reported for units within the same lot.(b)(4).
|
| |
|
Event or Problem Description
|
|
The reporter indicated that the surgeon implanted a 12.6mm vticm5_12.6; -6.5/2.5/102 (sphere/cylinder/axis) implantable collamer lens into the patient's left eye (os) on (b)(6) 2023.The surgeon reports the patient is hyperopic and showing residual cyl; has headaches and fatigue; steroids were prescribed.Lens remains implanted.If additional information is received a supplemental medwatch report will be submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: b5: the reporter indicated that the surgeon implanted a 12.6mm vticm5_12.6; -6.5/2.5/102 (sphere/cylinder/axis) implantable collamer lens into the patient's left eye (os) on (b)(6)2023.The surgeon reports the patient is hyperopic and showing residual cyl; has headaches and fatigue; steroids were prescribed.Reportedly, the lens was exchanged on (b)(6) 2023 for a same model and same length but different diopter lens.It has not been reported if the problem resolved.Claim# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Corrected data: d6a: should be corrected to 09-feb-2023.H6: 4629 should be corrected to 4627.Additional information: b5: the reporter indicated that the surgeon implanted a 12.6mm vticm5_12.6; -6.5/2.5/102 (sphere/cylinder/axis) implantable collamer lens into the patient's left eye (os) on (b)(6)2023.The surgeon reports the patient is hyperopic and showing residual cyl; has headaches and fatigue; steroids were prescribed.Reportedly, the lens was exchanged on (b)(6) 2023 for a same model and same length but different diopter lens.It is unclear whether lens removal and replacement occurred intraoperatively.Residual cylinder was present after the exchange.It has not been reported if the problem resolved.Claim# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: d9: return date: 25-aug-2023.H3 - device evaluation: the lens was returned in liquid in a vial.Visual inspection found the lens haptic torn and fiber on the lens.Dimensional and functional inspection found the lens to be within specifications.Claim#(b)(4).
|
| |
|