| Model Number |
GLX120208 |
| Medical Device Problem Code |
Failure to Advance (2524)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/09/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
The healthcare professional reported that during a coil embolization procedure targeting a type ii endoleak, after the guiding catheter was delivered from the left internal iliac artery (iia) to the type ii endoleak, a carnelian® marvel® microcatheter (tokai medical) was delivered to the target lesion and coil embolization was initiated.Several delta coils were implanted and one of the complaint coils, a 2mm x 8cm galaxy g3 xsft helical (glx120208 / 30871979) was used but it became impeded in the microcatheter and was unable to be delivered.It was replaced with another 2mm x 8cm galaxy g3 xsft helical (glx120208) from the same lot (30871979) but the same issue occurred and the coil was impeded in the microcatheter and could not be delivered.It was replaced with a delta coil (unspecified size) and this delta coil was delivered to the target lesion.It was reported that the left type ii endoleak was embolized.The guiding catheter was then delivered to the type ii endoleak from the right iia.The microcatheter was delivered and coil embolization was initiated.4mm x 15cm delta coil(s) were implanted and one complaint coil, a 3mm x 12cm deltafill 18 (dlf180312 / 30810117) was used but it also became impeded in the microcatheter.Another coil, a 4mm x 15cm deltafill 18 (dlf180415 / 30910222) was used but the same issue occurred.The microcatheter was replaced and coil embolization was resumed.The procedure was successfully completed.There was no negative patient impact reported.It was reported that a total of sixteen (16) spectra coils and five (5) interlock coils were used, of which, four (4) spectra coils became impeded in the microcatheter.On 17-mar-2023, pre-shipment photos of the four (4) spectra coils were added to the complaint.The product analysis team reviewed the photos.Based on the photo review completed on 29-mar-2023, the event related to three (3) of the four (4) the products have been deemed usfda reportable under title 21 cfr 803 with a classification of ¿malfunction.¿.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer¿s ref.No: (b)(4).Information regarding patient identifier, date of birth, age, gender, weight, race, and ethnicity were not provided.D.2b: procode is krd/hcg.E.1: the name, phone and email address of the initial reporter are not available / reported.H.3: the device is available to be returned for evaluation and testing.However, it has not been received to date as indicated as ¿other¿ in this section as the reason for non-evaluation.If the device returns, a device investigation will be performed.The pre-shipment photos of the complaint devices included in the file were reviewed.Based on the photos, the embolic coil component can be observed entangled with the device positioning unit (dpu) and the introducer sheath.The resistance heating (rh) coil was still attached to a severely stretched embolic coil.The blue fiber was observed to be exposed.The core wire was also observed to be severely kinked.A review of manufacturing documentation associated with this lot (30871979) presented no issues during the manufacturing or inspection processes related to the reported complaint.There were no nonconformances related to device manufacture or inspection.As part of the cerenovus quality process, all devices are manufactured, inspected, and released to approved specifications.The reported issue documented in the complaint that the embolic coil was impeded in the concomitant microcatheter was confirmed based on the damages observed in the photos provided in the complaint.This investigation was performed based only on the photo provided.If the product is received after this investigation, an assessment will be performed as per the conditions of the device returned.This is one of 3 products involved with the reported complaint.The associated manufacturer report numbers are: 3008114965-2023-00212, and 3008114965-2023-00213.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by cerenovus, or its employees that the report constitutes an admission that the product, cerenovus, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Missing information from this report is identified as blank; this information was not provided in the reported event or available at the time of report submission.The manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer¿s ref.No: (b)(4).The purpose of this mdr submission is to report the investigation finding of the returned device completed on 19-apr-2023, and the additional information received on 20-apr-2023.On 20-apr-2023, additional information was received.The information indicated that the resistance was first felt inside the microcatheter, however, no further details can be provided.It was not necessary to remove or replace the microcatheter.No damages were reported on the devices.Nothing was noted to be obstructing the microcatheter.Excessive force had not been applied to the device.The complaint device was returned for evaluation and analysis.The investigation finding is documented below.Investigation summary: a non-sterile 2mm x 8cm galaxy g3 xsft helical was received contained in the decontamination pouch.Visual inspection was performed.It was noted that the coil was entangled with the device positioning unit (dpu).The core wire was found with multiple kinks at the distal section of the marker band.The device was inspected under the microscope and it was observed that the embolic coil is severely stretched and is still attached to the resistance heating (rh) coil.The rh was not softened, an indication that the detachment process had not been initiated.It was also noted that the blue fiber from the coil is exposed.The conditions observed are consistent with the damages noted in the pre-shipment photos.The issue reported that the coil became impeded in the microcatheter and could not be delivered, could not be evaluated through functional testing due to all the damages observed on the coil and core wire components.According to the risk documentation, coil damage and device damage (i.E., core wire) are potential issues that can occur during microcoil placement due to the rotating hemostasis valve (rhv) being fastened too tightly and the introducer tip and microcatheter hub being misaligned.Also, friction and difficulty to advance are potential issues that can occur during microcoil placement due to continuous saline flush not being established, which can result in coil stretching.However, other factors not described in the event description may have contributed to the issue encountered during the procedure.Based on these findings, the customer complaint regarding a coil impeding in the microcatheter was confirmed.With the information available there is no indication that the issue reported in the complaint results from a defect inherently related to the device.A review of manufacturing documentation associated with this lot (30871979) presented no issues during the manufacturing or inspection processes related to the reported complaint.There were no nonconformances related to device manufacture or inspection.As part of the cerenovus quality process, all devices are manufactured, inspected, and released to approved specifications.It should be noted that multiple factors could cause product failure.The instructions for use (ifu) does contain the following recommendations: do not fasten the rhv valve too tightly around the introducer sheath since excessive pressure may cause damage to the introducer sheath and/or the microcoil as it is advanced into the infusion microcatheter.Additionally, if the introducer tip and microcatheter hub are misaligned, damage may occur to the microcoil as it passes through this transition.If unusual friction is noticed during advancement or retraction of the microcoil system through the introducer, open the rhv main valve, and partially withdraw the distal end of the introducer to expose its tip within the rhv.Tighten the rhv main valve and flush the y-connector of the rhv with sterile saline and verify that fluid exits the slit in the clear portion of the introducer.If unusual friction is still noticed during advancement or retraction of the microcoil system, verify flush lines are open and properly pressurized.Then slowly withdraw the entire microcoil system and examine for damage.Replace it with a new microcoil system.If friction still exists, withdraw, and examine the delivery catheter system.Based on the manufacturing documentation review, there is no indication that the event is related to the device manufacturing process.As part of the post market surveillance program, information from this complaint is trended for statistical signals and corrective / preventive action may be triggered at a later time.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no corrective actions will be taken at this time.Section e.1: initial reporter phone: (b)(6).This is one of 3 products involved with the reported complaint.The associated manufacturer report numbers are: 3008114965-2023-00211, 3008114965-2023-00212, and 3008114965-2023-00213.The manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer¿s ref.No: (b)(4).The purpose of this mdr submission is to report that the product was received in the product analysis lab on 12-apr-2023.The returned product is pending evaluation.A supplemental 3500a report will be submitted once the product investigation has been completed.This is one of 3 products involved with the reported complaint.The associated manufacturer report numbers are: 3008114965-2023-00212, and 3008114965-2023-00213.The manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|
| |
|
Search Alerts/Recalls
|
|