| Model Number |
222993 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/27/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
This is report 4 of 4 for (b)(4).It was reported by a healthcare professional in china that during a meniscal repair procedure on an unknown date, it was observed that two plates on the truespan meniscal repair system peek 12 degree device were deployed at the same time after the first firing.Changed to another truespan meniscal repair system peek 12 degree device to continue the surgery but the same problem happened again.Changed to truespan meniscal repair system peek 24 degree device to continue the surgery but its suture broke off when tightened the suture.And then use fastin rc 5mm orthocord w/o needles device but its suture also broke off.Another like device was used to complete the surgery.There were no adverse consequences to the patient nor surgical delay reported.No additional information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Udi: (b)(4).The lot number was unknown.The lot number was unknown; therefore, the expiration date, manufacturing site name and device manufacture date were unknown.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
|
| |
|
Event or Problem Description
|
|
This is report 4 of 4 for (b)(4).It was reported by a healthcare professional in china that during a meniscal repair procedure on (b)(6) 2023, it was observed that two plates on the truespan meniscal repair system peek 12 degree device were deployed at the same time after the first firing.Changed to another truespan meniscal repair system peek 12 degree device to continue the surgery but the same problem happened again.Changed to truespan meniscal repair system peek 24 degree device to continue the surgery but its suture broke off when tightened the suture.And then use fastin rc 5mm orthocord w/o needles device but its suture also broke off.Another like device was used to complete the surgery.There were no adverse consequences to the patient nor surgical delay reported.No additional information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Investigation summary the complaint device is not being returned, it was discarded by the customer, therefore unavailable for a physical evaluation.Since the complaint device was not discarded, we cannot determine a root cause for the reported failure.If additional information or the device is received in the future, we will reopen the complaint and perform the investigation as appropriate.Given that no lot number was provided, a manufacturing record evaluation (mre) review cannot be performed.If the lot number becomes available, the mre review will be performed.At this point in time, no corrective action is required, and no further action is warranted.However, depuy synthes mitek will continue to track any related complaints within this device family as a means of monitoring the extent with which this complaint is observed in the field.
|
| |
|